摘要 目前关于饮用水安全性的研究大都集中在出厂水水质上,对给水管网中水质的变化则重视不够,而给水管网在整个供水体系中占有重要的地位,对保障水质安全起关键作用。为此,结合北方某高校校园管网的水质监测数据,分析了管网水中异养细菌的生长情况及其影响因素。结果表明,沿水流方向管网水质变得越来越差,至管网末梢时自由余氯、浊度、细菌总数等都劣于国家饮用水卫生标准;影响该管网水质生物稳定性的主要因素为AOC、自由余氯、浊度、有机物等。 Presently, most concerns on the safety of drinking water are focused on the final treated water quality, while less attention is paid on the variation of water quality in water networks. Water networks are the important part of the water supply system, affecting the quality of drinking water. Based on the monitoring data on water quality in the network of a north college, the growth of heterotrophic bacteria and the affecting factors in the network water were analyzed. The results show that the water quality along the water flow direction becomes poorer and poorer, and free residual chlorine, turbidity, number of bacteria etc. in the network end are inferior to the national standard for drinking water hygiene. The key factors affecting the biostability of the water quality in the network are AOC, free residual chlorine, turbidity, organic matters etc.
出处 《中国给水排水》 CAS CSCD 北大核心 2006年第17期64-66,共3页 China Water & Wastewater
基金 天津市科委社会发展项目(033113111)
关键词 给水管网 饮用水 生物稳定性 AOC 异养细菌 water distribution network drinking water biostability assimilable organic carbon heterotrophic bacteria
  • 相关文献

参考文献2

二级参考文献12

  • 1George I, Petit M, Servais P. Use of enzymatic methods for rapid enumeration of coliforms in freshwaters [ J ]. Appl Environ Microbiol,2000,88:404 -413.
  • 2MeFeters G A,Pickett M,Broadaway S C,et al. Impact of chlorine injury on reaction kinetics of coliforms and E. coli in Colusure and LTB [ J ]. Water Sci Teehnol, 1997,35:419 -422.
  • 3Van Poucke S O,Nelis H J. A 210 - min solid phase cytometry test for the enumeration of Escherichia coli in drinking water [ J ]. Journal of Applied Microbiology,2000,89:390 - 396.
  • 4Rockabrand D,Austin T,Kaiser B,et al. Bacterial growth state distinguished by single-cell protein profiling:dose chlorination kill coliforms in municipal effluent [ J ]. Appl Environ Microbiol,1999 ,65 :4181 -4188.
  • 5Bellin T, Pulz M, Matussek A, et al. Rapid detection of enterohemorrhagic Escherichia coli by real-time PCB with fluorescent hybridization probes [J]. J Clin Microbiol,2001,39:370 - 374.
  • 6Carroll L E,Adams J K,Sulliban M,et al. A Real-time SYBR Green PCR Method for the Detection of Enterotoxigenic E. coli [ M ]. Orlando: ASM General Meeting,2001.
  • 7Regnault B, Martin-Delautre S, Lejay-Collin M,et al. Oligonucleotide probe for the visualization of Escherichia coli/Escherichia fergusonii cells by in situ hybridization:specificity and potential application [ J ]. Res Microbiol,2000,151:521 -533.
  • 8Delabre K, Dile V,De Roubin M R,et al. New Analytical Tools for Distribution System Surveillance Proceedings of AWWA-Annual Conference[ M ]. Washington DC: American Water Work Association ,2001.
  • 9Ootsubo M, Shimizu T, Tanaka R, et al. Oligonucleotide probe for detecting Enterobacteriaceae by in situ hybridization[ J ]. Journal of Applied Microbiology, 2002,93: 60-68.
  • 10Wallner G, Fuchs B, Spring S,et al. Flow sorting of microorganisms for molecular analysis [ J ]. Appl Environ Microbiol, 1997,63:4223 - 4231.

共引文献18

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部