期刊文献+

LD侧面泵浦Nd∶GdVO_4电光调Q激光器研究 被引量:3

Study on E-O Q-switched Nd∶GdVO_4 Laser Side-pumped by Laser Diode
下载PDF
导出
摘要 通过理论分析和实验研究,从泵浦效率、调Q性能、温度特性等几个方面比较了脉冲二极管泵浦Nd∶GdVO4激光器和Nd∶YAG激光器的差异;对Nd∶GdVO4激光器采用侧面泵浦的方式,电光调Q得到了输出能量27.5mJ,脉冲宽度为6.4ns,泵浦效率远高于Nd∶YAG激光器。 An E-O Q-switched Nd:GdVQ laser side- pumped by a diode-laser-array has been demonstrated. The characteristic difference between E-O Q-switched Nd: GdVQ and Nd: YAG laser is analyzed in pump efficiency, Q- switched performance and temperature characteristics. An output energy of 27.5mJ and a pulse width of 6.4ns are obtained. The pump efficiency is higher than Nd:YAG lasers.
出处 《激光与红外》 CAS CSCD 北大核心 2006年第B09期804-806,共3页 Laser & Infrared
关键词 ND:GDVO4 侧面泵浦 电光调Q Nd: GdvO4 side pumped E-O Q-switch
  • 相关文献

参考文献4

  • 1Jensen T,Ostroumov V G,Meyjn J P.Spectroscope characterization and laser performance of diode-laser-pumped Nd:GdVO4[J].Appl.Phys.B,1994,58 (5):373 -379.
  • 2W克希耐尔.固体激光工程[M].北京:科学出版社,2002..
  • 3John J Degnan.Theory of the Optimally Coupled Q -Switched Laser[J].1989,IEEE J.Quant.Electron.,1989,25:214.
  • 4金煜坚,王鹏飞,李久喜,冯江,李强.二极管泵浦固体激光器的热管理研究[J].激光与红外,2006,36(3):187-189. 被引量:4

二级参考文献3

  • 1W克希耐尔.固体激光工程[M].北京:科学出版社,2002..
  • 2H Azer,s Landre.Efficient Diode-pumped-mode Nd:YAG[J].Opt.Lett.,1992,17 (24):1785-1787.
  • 3P J Schneider.Conduction Heat Transfer[ M ].AddisonWesley Pub.Co.,1955.

共引文献42

同被引文献22

引证文献3

二级引证文献13