期刊文献+

住宅窗户的节能研究 被引量:14

STUDY ON THE ENERGY SAVING EFFECT OF RESIDENTIAL WINDOWS
下载PDF
导出
摘要 通过研究窗户热工参数的模拟计算方法,定义了表征窗户节能效果的两个参数:ER和ERC,并根据典型的建筑平面图,计算分析了多种因素对建筑节能的影响,得出了北京和哈尔滨两个城市的判断住宅窗户节能效果的经验回归公式,为设计人员和普通用户因地制宜地选择节能窗户提供了便捷有效的计算方法。 Two significant and creative parameters, ER and ERC were assigned to express the energy saving effect of a particular window through researching the simulating calculation method of the heat parameters of windows. The effects of many factors to the building' energy saving were analyzed according to the typical conditions buildings, and then conclude the experiential regression formulas on the judgment in windows' energy saving effect for the cities of Beijing and Harbin respectively. The ER equation provides a simple and effective way for designers or consumers to choose right energy saving windows, adjusting measures to local conditions.
出处 《太阳能学报》 EI CAS CSCD 北大核心 2006年第1期101-105,共5页 Acta Energiae Solaris Sinica
关键词 窗户节能 传热系数(U) 太阳得热系数(G) ER window energy savings U-factor G-factor ER
  • 相关文献

参考文献7

  • 1王苏颖,狄洪发.美国、加拿大窗户能耗等级评价体系综述[J].太阳能学报,2002,23(4):431-436. 被引量:4
  • 2杨云桦,狄洪发.低辐射能玻璃窗的节能研究[J].太阳能学报,2001,22(3):296-301. 被引量:28
  • 3Finlayson E U, Arasteh D K, Huizenga C. Window 4.0:Documentation of calculation procedures[R], 1993.
  • 4Reilly M S, Winkelmann F C, Arasteh D K. Modefing windows in DOE-2.1E energy and buildings[M]. 1995, (22) :59-66.
  • 5魏玲,何嘉鹏.南京地区冬季窗节能研究[J].太阳能学报,2002,23(3):336-339. 被引量:8
  • 6Carpenter S C, McGowan A G, Miller S R. Window annual energy rating systems: what they tell us about residential window design and selection [J]. Ashraetransactions, 1998, 104(10) : 806-813.
  • 7E E. Calculating the window energy rating: Report prepared for natural resources Canada [R], Ottawa, Ontario, Canada,by enennodal engineering, 1989.

二级参考文献14

  • 1张寅平.热镜膜的应用研究--热镜膜制备工艺探索及性能研究、半透明薄膜光学性质、热射性质及其测定方法研究:博士学位论文[M].合肥:中国科技大学,1991..
  • 2[1]Carpenter S C, McGowan A G, Miller S R. Window annual energy rating systems: what they tell us about residential window design and selection[J]. ASHRAE Transactions, 1998, 104(10): 806-813.
  • 3[2]Mayo T, Carpenter S C. Canadian project to develop energy labels for windows[J]. ASHRAE Transactions, 1989, 95(2): 772-775.
  • 4[3]EE. Calculating the window energy rating. Report prepared for Natural Resources Canada[R]. Canada, Enermodal Engineering, 1989.
  • 5[4]CSA.CSA standard A440-M98. Windows and CSA standard A440.2. Energy performance evaluation of windows and sliding glass doors[S]. Canadian Standards Associatin, Rexdale, Ontario, Canada. 1998.
  • 6[5]EE. Development of a cooling energy rating system for windows. Report prepared for Natural Resources Canada[R]. Canada, Enermodal Engineering, 1993.
  • 7[6]Henry R, Dubrous F. Are window energy performance selection requirements in line with product design in heating-dominated climates[J]. ASHRAE Transactions, 1998, 104(10): 799-805.
  • 8[7]Crooks B, Larsen J, Sullivan R, et al. NFRC efforts to develop a residential fenestration annual energy rating methodology[A]. Proceedings of the Window Innovations Conference[C], Canada. 1995.
  • 9[8]NFRC. NFRC 900: Procedure for determining the annual heating and cooling energy ratings of fenestration products used in residential dwellings[M]. Silver Spring, Md.: National Fenestration Ration Council. 1997.
  • 10[9]Reilly S,Hawthorne W.The impact of windows on residential energy use[J].ASHRAE Transactions,1998,104(2).