摘要
文章提出高准确度电能表检定装置综合误差和不确定度的计算方法及计算公式。并列举了0·006级三相装置的具体计算实例,可供建标和比对工作中参考。
The paper put forward the calculating method and formula of synthetic error and uncertainty degree of calibration device for high accuracy three - phase watt - hour meter, and took the specific calculation of 0.006 level three - phase device as an example.
出处
《电力设备》
2006年第10期37-40,共4页
Electrical Equipment
关键词
高准确度三相电能表
检定装置
不确定度
分析计算
综合误差
calibration device for high accuracy three - phase watt - hour meter
uncertainty degree analysis and calculation
synthetic error