摘要
结合实际情况,对注水管网系统中水力损失情况进行分析,并进行室内模拟实验,对现场生产提供理论依据,合理布置管网和确定管网中各管段的管径,做到既满足各注水井的压力和配注量要求,又不使某些配水间的系统压力损失过高。
Based on the actual issues, analysed hydropower loss during the operation of a pipeline network system. And lab simulation tests were conducted in order to offer theoretic evidence, distribute the network rationally and determine the diameter of each section of the pipeline.Thus,it will not only meet the pressure of each injection well and volume of injection allocation, but also reduce the system pressure loss of a water injection zone.
出处
《管道技术与设备》
CAS
2006年第5期10-11,共2页
Pipeline Technique and Equipment
关键词
注水管网
水力损失
模拟实验
water flooding pipeline network
hydropewer loss
simulation tests