期刊文献+

螺旋CT肝脏增强扫描造影剂的应用 被引量:5

Contrast Material Injection Protocols in Hepatic Enhancement with Spiral CT
下载PDF
导出
摘要 通过对40例肝脏扫描时间-密度曲线分析,找出较适合螺旋CT肝脏扫描的造影剂应用技术,测量了单、双时相注射的肝脏、主动脉和脾脏的增强值,并对最高增强值及对应时间、平衡期和增强值30Hu以上平衡期适合扫描的时间进行了分析,单时相注射的肝脏最高增强值高于双时相注射,到达时间比双时相早15秒,单时相注射平衡期比双时相提前20秒,增强值30Hu以上到平衡期时间单、双时相注射分别为35s和50s,所以,单时相注射更适于螺旋CT肝脏扫描。 The issue of optimal intravenous administration of contrast material for liver computed tomography(CT) had long been debated.The introduction of spiral CT had added to its complexity. The optimal techniques of contrast material injection were found for the spiral CT of the liver using time-density analysis in 40 patients. The enhancement of the liver, aorta and spleen after uni-and biphasic injection was measured. and the mean peak enhancement. the time to peak enhancement, equilibrium, and the time from enhancement above 30Hu to equilibrium were compared. The mean peak enhancement of the liver in uniphasic injection was greater than that in biphasic injection, and the time to peak enhancement was 15 seconds earlier than biphasic injection, equilibrium was 20 seconds earlier than biphasic injection. The time from enhancement above 30Hu to equilibrium in uniphasic and biphasic injection was 35 and 50 seconds. Respectively. Uniphasic injection was more suitable for the spiral CT of the liver, and biphasic injection should be chosen in conventional CT.
出处 《中国医学影像学杂志》 CSCD 1996年第3期143-145,共3页 Chinese Journal of Medical Imaging
关键词 螺旋CT 造影剂 肝脏 spiral computed tomography contrast material liver
  • 相关文献

同被引文献35

  • 1赵绍宏.肝脏肿瘤的CT增强研究[J].中国医学影像学杂志,1996,4(1):54-55. 被引量:3
  • 2严福华,曾蒙,苏周,康荣.螺旋CT肝脏检查中技术参数的选择──时间-密度曲线的分析[J].临床放射学杂志,1996,15(5):290-293. 被引量:62
  • 3林贵.肝肿瘤的微血管结构和血供[J].中华放射学杂志,1985,19(5):257-257.
  • 4[1]Baron RL.Understanding and optimizing use of contrast material for CT of the liver.AJR,1994,163(2):323.
  • 5[2]Silverman PM,Cooper CJ,Trock B,et al.The optimal temporal window for CT of the liver using a time-density analysis:Implications for helical CT.JACT,1995,19(1):73.
  • 6[3]Berland LL.Slip-ring and conventional dynamic hepatic CT: Contrast material and timing considerations.Radiology,1995,195(1):1-8.
  • 7[4]Chamber TP,Baron RL,Lush RM. Hepatic CT enhancement Part I . Alterations in contrast material volume and rate of injection within the same patients.Radiology,1994,193(2):518.
  • 8[5]Silverman PM,Cooper CJ,Welteman DI,et al.Helical CT: Practical consideration and potential pitfalls.Radiographics,1995,15(1):25.
  • 9[6]Silverman PM,Brown B,Wray H,et al.Optimal contrast enhancement of the liver using helical (spiral)CT: Value of smartprep.AJR,164(5):1169-1171.
  • 10[7]Kopka L,Funke M,Vosshenrich R,et al.Helical CT of the liver:evaluation of injection flow rate,mode,and scan delay with a reduced-volume contrast medium bolus.JACT,1995,19(3):406-411.

引证文献5