期刊文献+

多层螺旋CT血管成像评价冠状动脉血管旁路移植术 被引量:2

Evaluation of coronary bypass grafts with multislice spiral CT angiography
下载PDF
导出
摘要 目的评价多层螺旋CT(MSCT)冠状动脉成像对冠状动脉桥血管的临床价值。方法28例患者的69条冠状动脉桥血管接受16层和64层螺旋CT冠状动脉成像。对桥血管成像进行影像质量评估,使用多元线性回归方法评估患者心率、心率波动幅度、呼吸运动以及不同CT扫描机对冠状动脉成像质量的影响。其中10位患者26条桥血管的CT血管成像结果与冠状动脉血管造影结果进行对比。结果呼吸运动伪影与冠状动脉桥血管成像质量呈负相关,相关系数为-0.838。64层CT扫描机的影像质量高于16层CT扫描机的影像质量。以CAG结果为参考标准,MSCT冠脉成像诊断桥血管及吻合口狭窄的特异性和敏感性分别为95.7%和92.3%。结论MSCT可以提供可靠的冠状动脉桥血管影像以及较高的诊断准确性。 Objective To evaluate the value of muhislice CT anglography (CTA) for assessment of coronary artery bypass graft (CABG). Methods A total of 28 patients with 69 coronary artery bypass grafts were examined by CTA with 16-slice and 64-slice CT, in which 26 coronary artery bypass grafts of 10 patients coronary artery bypass grafts were examined by coronary angiography as well. Using multiple linear regression to evaluate the effect of patient's heart rate, fluctuation of heart rate, breathing movement and different CT scanners on image quality of CT coronary angiogram. Results The patient's breathing movement was negatively related to the image quality, the value of standardized coefficients was -0. 838. The image quality of 64-slice CT was higher than that of 16-slice CT. Taken the CAG as reference standard, the sensitivity and specificity of CT in evaluating the anastomosis and bypass grafts were 95. 7% and 92. 3% respectively. Conclusion MSCT can provide high image quality of CABG, which has great potential value in the follow-up of this disease.
出处 《中国医学影像技术》 CSCD 北大核心 2006年第10期1496-1499,共4页 Chinese Journal of Medical Imaging Technology
关键词 体层摄影术 X线计算机 冠状血管造影术 冠状动脉旁路移植术 Tomography, X-ray computed Coronary angiography Coronary artery bypass graft
  • 相关文献

参考文献6

  • 1Nieman K,Rensing B,van Geuns R,et al.Non-invasive coronary angiography with multislice spiral computed tomography:impact of heart rate[J].Heart,2002,88(5):470-474.
  • 2Hoffmann MH,Shi H,Manzke R,et al.Noninvasive coronary angiography with 16-detector row CT:effect of heart rate[J].Radiology,2005,234(1):86-97.
  • 3Ropers D,Ulzheimer S,Wenkel E,et al.Investigation of aortocoronary artery bypass grafts by multislice spiral computed tomography with electrocardiographic-gated image reconstruction[J].Am J Cardiol,2001,88(7):792-795.
  • 4Schlosser T,Konorza T,Hunold P,et al.Noninvasive visualization of coronary artery bypass grafts using 16-detector row computed tomography[J].J Am Coll Cardiol,2004,44(6):1224-1229.
  • 5宋玮,金叔宣,杜勇平,刘建平,何奔,王彬尧.16排CT对冠状动脉桥血管病变评估的临床应用价值[J].中华心血管病杂志,2005,33(8):704-707. 被引量:14
  • 6方文春,袁旭春,夏丽天,邱洁玲.16层螺旋CT血管成像检查评价冠状动脉搭桥血管[J].中国介入影像与治疗学,2005,2(4):271-273. 被引量:13

二级参考文献9

  • 1方文春,龚静山,夏丽天,吴斌,邱洁玲,袁旭春.不同重建技术在多排螺旋CT冠状动脉造影中的应用[J].实用放射学杂志,2004,20(10):931-934. 被引量:8
  • 2Grondin CM, Campeau L, Thornton JC, et al. Coronary artery bypass grafting with saphenous vein.Circulation,1989,79(6 pt 2):124-129.
  • 3Dion R, Glineur D, Derouck D, et al. Complementary saphenous grafting: long-term follow-up.J Thorac Cardiovasc Surg,2001,122:296-304.
  • 4Schwartz L, Kip KE, Frye RL, et al. Coronary bypass graft patency in patients with diabetes in the Bypass Angioplasty Revascularization Investigation (BARI).Circulation,2002,106:2652-2658.
  • 5Nieman K, Cademartiri F, Lemos PA, et al. Reliable noninvasive coronary angiography with fast submillimeter multislice spiral computed tomography.Circulation,2002,106:2051-2054.
  • 6Ropers D, Baum U, Pohle K, et al. Detection of coronary artery stenoses with thin-slice multi-detector row spiral computed tomography and multiplanar reconstruction. Circulation, 2003,107:664-666.
  • 7Schlosser T, Konorza T, Hunold P, et al. Noninvasive visualization of coronary artery bypass grafts using 16-detector row computed tomography. J Am Coll Cardiol,2004,44:1224-1229.
  • 8Nieman K, Rensing BJ, Van Geuns RJ, et al. Non-invasive coronary angiography with multislice spiral computed tomography: impact of heart rate. Heart, 2002,88:470-474.
  • 9孙国平,陈宇,徐坚民,饶梓彬,龚静山,李圣峰,张景忠.冠状动脉钙化多层螺旋CT检查及与冠状动脉造影的对比研究[J].中国医学影像技术,2004,20(5):702-704. 被引量:3

共引文献24

同被引文献18

  • 1方文春,袁旭春,夏丽天,邱洁玲.16层螺旋CT血管成像检查评价冠状动脉搭桥血管[J].中国介入影像与治疗学,2005,2(4):271-273. 被引量:13
  • 2张宗军,卢光明.双源CT及其临床应用[J].医学研究生学报,2007,20(4):416-418. 被引量:106
  • 3李鹏雨,李坤成,杜祥颖,刘佳宾,曹丽珍,杨延辉.64层螺旋CT在冠状动脉搭桥术后随访中的初步应用[J].放射学实践,2007,22(4):376-379. 被引量:6
  • 4Tanja S, Meyer, Stefan Martinoff, Martin Hadamitzky, et al. Improved noninvasive assessment of coronary artery bypass grafts with 64-slice computed tomographic angiography in an unselected patient population [J]. J Am Coll Cardiol, 2007,49(9) :946-950.
  • 5Ropers D, Ulzheimer S, Wenkel E, et al. Investigation of aortocoronary artery bypass grafts by multislice spiral computed tomography with electrocardiographic-gated image reconstruction [ J]. Am J Cardiol, 2001,88 (7) : 792-795.
  • 6Nieman K, Pattynama P, Rensing B, et al. Evaluation of patients after coronary artery bypass surgery: CT angiographic assessment of grafts and coronary arteries [J] .Radiology, 2003,229(3 ) :749-756.
  • 7Min-Ho Song, Toshiaki ho, Takashi Watanabe, et al. Multidetector computed tomography versus coronary angiogram in evaluation of coronary artery bypass grafts [J]. Ann thorac Surg,2005,79(2): 585-588.
  • 8Paul Stolzmann,Hans Scheffel,Thomas Schertler,Thomas Frauenfelder,Sebastian Leschka,Lars Husmann,Thomas G. Flohr,Borut Marincek,Philipp A. Kaufmann,Hatem Alkadhi.Radiation dose estimates in dual-source computed tomography coronary angiography[J]. European Radiology . 2008 (3)
  • 9Hans Scheffel,Hatem Alkadhi,André Plass,Robert Vachenauer,Lotus Desbiolles,Oliver Gaemperli,Tiziano Schepis,Thomas Frauenfelder,Thomas Schertler,Lars Husmann,Jürg Grunenfelder,Michele Genoni,Philipp A. Kaufmann,Borut Marincek,Sebastian Leschka.Accuracy of dual-source CT coronary angiography: first experience in a high pre-test probability population without heart rate control[J]. European Radiology . 2006 (12)
  • 10Thomas G. Flohr,Cynthia H. McCollough,Herbert Bruder,Martin Petersilka,Klaus Gruber,Christoph Sü?,Michael Grasruck,Karl Stierstorfer,Bernhard Krauss,Rainer Raupach,Andrew N. Primak,Axel Küttner,Stefan Achenbach,Christoph Becker,Andreas Kopp,Bernd M. Ohnesorge.First performance evaluation of a dual-source CT (DSCT) system[J]. European Radiology . 2006 (6)

引证文献2

二级引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部