急性心肌梗死介入治疗中远端保护装置的应用进展
Distal Protection Devices During Primary Angioplasty in Acute Myocardial Infarction
摘要
远端血管栓塞以及无复流现象是介入治疗的研究热点问题。远端保护装置在减少这一现象中发挥着重要作用,现就远端保护装置的作用做一简要阐述。
Distal embolization and no-flow phenomenon are important aspects of interventional therapy. Distal protection devices can reduce this phenomenon. This article summarizes the role of distal protection device.
出处
《心血管病学进展》
CAS
2006年第6期713-715,共3页
Advances in Cardiovascular Diseases
关键词
急性心肌梗死
远端栓塞
远端保护装置
介入治疗
acute myocardial infarction
distal embolization
distal protection device
参考文献19
-
1Michels KB,Yusuf S.Does PTCA in acute myocardial infarction affect mortality and reinfarction rates? A quantitative overview (meta2 analysis) of the randomized clinical trials[J].Circulation,1995,91:476-485.
-
2Zijlstra F,de Boer MJ,Ottervanger JP,et al.Primary coronary angioplasty versus intravenous streptokinase in acute myocardial infarction:Differences in outcome during a mean follow-up of 18 months[J].Coron Artery Dis,1994,5:707-712.
-
3Saber RS,Edwards WD,Bailey KR,et al.Coronary embolization after balloon angioplasty or thrombolytic therapy:An autopsy study of 32 cases[J].J Am Coll Cardiol,1993,22:1283-1288.
-
4Grines C,Cox D,Stone D,et al.Stent PAMI:12-month results and predictors ofmortality[J].J Am Coll Cardiol,2000,35(suppl2):72.
-
5黄铮,陈红武,Osamu Katoh,Shigeru Nakamura.远端血管保护装置Guard Wire在急性心肌梗死急诊介入治疗中的应用[J].中华心血管病杂志,2003,31(11):830-833. 被引量:14
-
6Webb JG,Carere RG,Virmani R,et al.Retrieval analysis of particulate debris after saphenous vein graft intervention[J].J Am Coll Cardiol,1999,34:468-475.
-
7王乐丰,杨新春,佟子川,徐立,吴兆苏,张维君,王红石,邹阳春,葛永贵,王立中,李惟铭,周旭,连勇,栾与英.远端保护装置Angioguard^(TM)在急性心肌梗死急诊经皮冠状动脉介入治疗中的应用[J].中国介入心脏病学杂志,2003,11(3):120-122. 被引量:11
-
8Pasquetto G,Reimers B,Favero L,et al.Distal filter protection during percutaneous coronary intervention in native coronary arteries and saphenous vein grafts in patients with acute coronary syndromes[J].Ital Heart J,2003,4(9):614-619.
-
9Abbo KM,Dooris M,Glazier S,et al.Features and outcome of no-reflow after percutaneous coronary intervention[J].Am J Cardiol,1995,75:778-782.
-
10Topol EJ,Yadav JS.Recognition of the importance of embolization in atherosclerotic vascular disease[J].Circulation,2000,101:570-580.
二级参考文献21
-
1Morishima 1, Sone T, Okumura K, et al, Angiographic no-reflow phenomenon as a predictor of adverse long-term outcome in patients treated with percutaneous transluminal coronary angioplasty for first acute myocardial infarction. JACC, 2000,36:1202-1209.
-
2Tanaka A, Kawarabayashi T, Nishibori Y, et al, No-reflow phenomenon and lesion morphology in patients with acute myocardial infarction. Circulation, 2002, 105:2148-2152.
-
3vHof AM J, Liem A, Suryapranata H, et al, Angiographic assessment of myocardial reperfusion in patients treated with primary angioplasty for acute myocardial infarction: myocardial brush grade. Circulation,1998,97 : 2302-2306.
-
4Iwakura K, Ito H, Nishikawa N, et al, Early temporal changes in coronary flow velocity patterns in patients with acute myocardial infarction demonstrating the “no-reflow” phenomenon. Am J Cardiol,1999,84:415-419.
-
5Yamada DM, Topol EJ. Microvascular embolization in acute coronary syndromes. Acut Cor Syn, 2001,4:1-17.
-
6Rezkalla SH, Kloner RA, No-reflow phenomenon. Circulation, 2002,105 : 656-662.
-
7Michaels AD, Gibson CM, Barton HW. Microvascnlar dysfunction in acute myocardial infarction: focus on the roles of platelet and inflammatory mediators in the no-reflow phenomenon. Am J Cardiol,2000,85:50B-60B.
-
8Bain DS, Wahr D, George B, et al, Randomized trial of a distal embolic protection device during percutaneous interven of saphenous vein aorto-coronary bypass grafts. Circulalion, 2002,105:r13-r18.
-
9U.S. SAPPHIRE Study Group. Preliminary results of carotid stenting with ANGIOGUARD XP emboli protection guidewire vs. surgery for carotid artery blockages in high risk patients. AHA, 2002,11, chicago,IL.
-
10Michels KB;Yusuf S.Does PTCA in acute myocardial infarction affect mortality and reinfarction rates? Aquantitative overview (meta-analysis) of the randomized clinical trials[J],1995(91).
共引文献24
-
1颜红兵,刘爱军,柯元南,曾玉杰,高焱莎,李宪伦.两种远端保护装置在预防无复流中的初步应用结果[J].中国循环杂志,2004,19(z1):13-15. 被引量:2
-
2韩艳丽,陈玉国,李贵双,李继福,许维亮,王营.小剂量尿激酶联合合贝爽冠状动脉内注射对PCI无再流现象疗效的临床评价[J].中国中西医结合影像学杂志,2003,1(4):209-211. 被引量:2
-
3高延,李成祥,王海昌,贾国良,曹丰,冯旭阳.远端保护装置对急性心肌梗死患者介入治疗心肌的保护作用[J].第四军医大学学报,2004,25(23):2148-2151. 被引量:1
-
4王海昌,曹丰,李成祥.远端保护装置在介入治疗中的应用进展[J].心脏杂志,2005,17(1):74-76. 被引量:2
-
5段云燕,张军,周晓东,李军,李红玲,刘丽文,朱霆.超声心动图评价冠状动脉远端保护装置对急性心肌梗死患者左室重构的作用[J].中国医学影像技术,2005,21(2):219-222. 被引量:1
-
6段云燕,张军,周晓东,刘丽文,朱永胜,李成祥,高延,郭宣,左蕾.超声心动图对急性心肌梗死患者应用冠状动脉远端保护装置的监测与评价[J].中华超声影像学杂志,2005,14(3):176-179. 被引量:2
-
7陆程翔.远端保护装置在冠心病介入治疗中的应用进展[J].福建医药杂志,2005,27(2):153-155.
-
8王晓燕,王海昌,李成祥,郭文怡,冯旭阳,李伟,党米婵.远端保护装置在急性心肌梗死患者介入治疗中的疗效观察与护理[J].现代护理,2005,11(8):617-618.
-
9师文彦.急诊介入治疗中无复流现象的预后及药物处理初步探讨[J].中国医药导刊,2005,7(4):253-254. 被引量:3
-
10覃远文.急性冠脉综合征治疗进展[J].中国医学文摘(老年医学),2005,14(3):157-160.
-
1张成,王伟.远端保护装置在冠心病介入治疗中的应用[J].中国心血管杂志,2007,12(1):67-69.
-
2孙守刚,白锋,胡浩.远端保护装置在急性心肌梗死急诊经皮冠状动脉介入治疗中的应用[J].兰州大学学报(医学版),2007,33(1):89-92.
-
3王明.DPD对ACS急诊PCI术神经内分泌因子及并发症的影响[J].中国现代医生,2011,49(31):27-29.
-
4彭锦妹.替罗非班在急性ST段抬高心肌梗死介入治疗中的应用观察及护理[J].临床合理用药杂志,2011,4(22):103-104. 被引量:2
-
5高峻,徐玉云,张曰欣.急性心肌梗塞介入治疗时应用远端保护装置的围术期护理[J].健康大视野(医学版),2006,14(8):62-62.
-
6颜红兵,刘爱军,柯元南,曾玉杰,高焱莎,李宪伦.两种远端保护装置在预防无复流中的初步应用结果[J].中国循环杂志,2004,19(z1):13-15. 被引量:2
-
7唐文杰,高鹏,王亚冰,马妍,焦力群.颈动脉次全闭塞患者支架置入术效果分析[J].中国脑血管病杂志,2016,13(10):545-548. 被引量:8
-
8王海昌,曹丰,李成祥.远端保护装置在介入治疗中的应用进展[J].心脏杂志,2005,17(1):74-76. 被引量:2
-
9王国富.杂交手术在下肢动脉硬化闭塞症中的应用体会[J].浙江创伤外科,2012,17(3):336-337. 被引量:1
-
10陈玉国,徐峰,张运,李继福,李贵双,纪求尚,刘同涛,吕瑞娟,孙袆,李瑞建.远端保护装置在急性心梗经皮冠状动脉介入治疗中的应用[J].临床急诊杂志,2004,5(6):13-14.