期刊文献+

HD02型血透监测仪对血液透析患者内瘘的监测 被引量:24

Surveillance of arteriovenous fistula in hemodialysis patients using HD02 monitor
原文传递
导出
摘要 目的评价应用超声稀释法的HD02型血透监测仪对血液透析患者内瘘监测的效能。方法使用HD02型血透监测仪对90例长期维持性血液透析(MHD)患者在透析期间进行内瘘再循环、流量及心输出量等监测。分析影响内瘘流量的相关因素。结果4例患者出现再循环,占4.44%,且均大于5%(非尿素稀释法异常标准)。21例患者内瘘血流量<500 ml/min,占23.33%;3例>2000 ml/min,占3.33%。影响内瘘流量的Logistic回归分析显示,年龄、性别、透析时间、内瘘使用时间、平均动脉压均与内瘘流量下降无相关:低心输出量和糖尿病与内瘘流量下降相关。33例患者心输出量<4 L/min,占36.67%,提示部分患者在透析期间处于低心输出量状态。其中低心输出量的8例患者接受心脏彩色多普勒超声检查,均发现有不同程度的室间隔肥厚、瓣膜区钙化和反流、左室舒张功能不全等心血管功能和形态学改变。结论超声稀释法是一项操作简便、非侵入及实用的内瘘监测方法。自体动静脉内瘘在有足够血流情况下,再循环率低。低心输出量和糖尿病与内瘘流量下降相关。 Objective To evaluate the efficacy of HD02 hemodialysis monitor by means of ultrasound dilution method in surveillance of arteriovenous fistula. Methods Re-circulation, blood flow of fistula and cardiac output of 90 maintenance hemodialysis (MHD) patients were measured by HD02 hemodialysis monitor during hemodialysis session. Concerning factors of fistula blood flow were analyzed. Results Fistula re-circulation(〉5%) occurred in 4 patients (3.33%). Blood flow (Qa) less than 500 ml/min was found in 21 patients(23.33%), and more than 2000 ml/min in 3 patients (3.33%). The logistic regression analysis revealed that age, sex, time of hemodialysis, time of fistula creation and mean arterial pressure were not significantly correlated, but low cardiac output and diabetes were significantly correlated to the decrease of fistula blood flow. Cardiac output less than 4 L/min was found in 33 patients(36.67% ), suggesting that low cardiac output status existed in some MHD patients during hemodialysis session. Cardiac color Doppler was performed in 8 low cardiac output status patients and the result showed changes of cardiac function and structure such as interventricular septum pachynsis, cardiac valve calcification, back-streaming and left ventricle diastolic insufficiency. Conclusions Ultrasound dilution is a simple non-invasive surveillance method for hemodialysis fistula. The re-cireulation rate is low when A-V fistula obtaining enough blood flow. Low cardiac output and diabetes are significantly correlated with the decrease of fistula blood flow.
出处 《中华肾脏病杂志》 CAS CSCD 北大核心 2006年第12期730-733,共4页 Chinese Journal of Nephrology
关键词 动静脉瘘 肾透析 超声稀释技术 Arteriovenous fistula Renal dialysis Ultrasound dilution technology
  • 相关文献

参考文献13

  • 1National Kidney Foundation : K-DOQI clinical practice guidelines for vascular access : update 2000. Am J Kidney Dis, 2001,37 Suppl 1: S137-S181.
  • 2Jindal KK, Ethier J, Lindsay RM, et al. Clinical practice guidelines for vascular access. Canadian Society of Nephrology. J Am Soc Nephrol, 1999, 10 Suppl 13: S287-S321.
  • 3Besarab A. Access monitoring is worthwhile and valuable.Blood Purif, 2006,24:77-89.
  • 4Depner TA, Krivitski NM, MacGibbon D. Hemedialysis access recirculation measured by ultrasound dilution. ASAIO J, 1995,41: M749-M753.
  • 5Krivitski NM. Theory and validation of access flow measurement by dilution technique during hemodial-ysis. Kidney Int, 1995,48 : 244-250.
  • 6Krivitski NM. Novel method to measure access flow during hemodialysis by ultrasound velocity dilution technique. ASAIO J, 1995, 41: M741-M745.
  • 7Depner TA, Krivitski NM. Clinical measure mental blood flow in hemodialysis access fistulae and grafts by ultrasound dilution. ASAIOJ, 1995, 41: M745-M749.
  • 8Tonelli M, Jindal K, Hirsch D, et al. Screening for subclinical stenosis in native vessel arteriovenous fistulae. J Am Soc Nephrol, 2001,12:1729-1733.
  • 9张颖秋,梅长林,叶朝阳.维持性血透患者血管通路两种再循环率测定方法的比较[J].第二军医大学学报,2005,26(7):812-814. 被引量:10
  • 10Basile C, Ruggiefi G, Vernaglione L, et al. A comparison of methods for the measurement of hemodialysis access recirculation. J Nephrol, 2003, 16: 908-913.

二级参考文献7

  • 1Lopot F, Nejedly B, Sulkova S, et al.Comparison of different techniques of hemodialysis vascular access flow evaluation [J]. Int J Artif Organs, 2003,26(12):1056-1063.
  • 2Schneditz D, Kaufman AM, Levin N. Surveillance of access function by the blood temperature monitor [J]. Semin Dial, 2003,16(6):483-487.
  • 3Besarab A, Lubkowski T, Ramanathan S, et al. Detection of access strictures and outlet stenoses in vascular accesses. Which test is best [J]. ASAIO J, 1997,43(2):69-74.
  • 4Sherman RA. The measurement of dialysis access recirculation [J]. Am J Kidney Dis, 1993,22(4):616-621.
  • 5Lindsay RM, Burbank J, Brugger J, et al. A device and a method for rapid and accurate measure of access recirculation during hemodialysis [J]. Kidney Int, 1996,49(4):1152-1160.
  • 6Magnasco A, Alloatti S, Bonfant G, et al. Glucose infusion test:A new screening test for vascular access recirculation [J]. Kidney Int, 2000,57(5):2123-2128.
  • 7Besarab A, Sherman R. The relationship of recirculation to access blood flow [J]. Am J Kidney Dis, 1997,29(1):223-229.

共引文献9

同被引文献181

引证文献24

二级引证文献244

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;