摘要 采用ICP-AES技术,对纯度为99.5%~99.99%的氧化镱中14个稀土杂质元素的直接测定进行了研究。对分析线的选择、工作功率、载气流量、进样浓度等条件进行了试验。本法条件下,各分析元素的相对标准偏差小于8.0%,标准加入回收率在90%~108%之间。并对实际样品进行了测定,结果满意。 In this paper, the direcet determination of 14 rare earth elements in ytterbium oxide of 99.5%~ 99.99% by ICP-AES was studied. The experiments for the selection of analysis lines, working power, the volume of flow of carrier gas, and sampling concentration ,etc. were carried out. Under the given condition, the relative standard deviation was less than 8.0%, standard addition recoveries were in the range of 90~108%.
作者 练萍 钟海山
出处 《稀土》 EI CAS CSCD 北大核心 2006年第6期86-87,98,共3页 Chinese Rare Earths
关键词 ICP-AES 直接测定 氧化镱 稀土元素 ICP-AES direct determination ytterbium oxide rare earth elements