期刊文献+

办公建筑的天然采光实验研究 被引量:8

Experimental Study on Daylighting of Office Buildings
原文传递
导出
摘要 对办公建筑的天然采光进行了实验研究。首先,从理论和模拟两个角度分析了模型和原型的照度分布相似性,并建立了办公室实验模型;其次,由于天空状态的多变性,提出用天然采光系数替代照度进行实验验证;最后,通过实验测试,分别验证了窗墙比、窗台高和透光率对室内照度分布的影响,分析了产生各种误差的原因,结果表明误差均在可接受范围内。 This paper provides an experimental study on day lighting of office buildings. Firstly, the illuminance distribution similarity of the model and ante type is validated with theoretical and simulating study, based on which the office model is established. Then, daylight factor is put forward to substitute illuminance for experimental analysis. Lastly, the study of the influence of window-to-wall ratio, sill high and transmittance on indoor illuminance distribution is carried out respectively with experimental test, and the reasons of testing difference are analyzed. The results show that the testing difference is acceptable.
出处 《建筑科学》 北大核心 2006年第6期14-17,33,共5页 Building Science
基金 北京市哲学社会科学"十一五"规划项目(06BaJG0095) "北京市供热 供燃气 通风与空调工程"重点实验室资助
关键词 办公建筑 天然采光 实验研究 voffice building day lighting experimental study
  • 相关文献

参考文献4

二级参考文献15

  • 1Hopkirk N. Daylighting . In: Hastings R, editor.Passive solat cimmercial and institutional buildings: a sourcebook of examples and design insights [M]. IntEnergy Agency(IEA), 1994.
  • 2Jiraratananon S. Linghting and daylighting in buildings in energy consrvation in buildings [A] . Mohanty B,Bouix P, editors. Proceedings of the 5th Asian School[C], Bangkok; AIT; 15-23 June , 1987, 34-44.
  • 3Simons R H, Bean. A R. Lighting engineering [M].Architectural Press, 2001, 455.
  • 4Lynes J A. A squence for daylighting design [J].Lighting Research and Technology, 1979, 11 (2):106-116.
  • 5Crisp V H C, Littlefir P J. Average daylight factor prediction [A]. CIBSE Natioanl Lighting Confernce[C], 1984, 28-39.
  • 6Bodart M, De Herde A. Global energy savings in offices buildings by the use of daylighting [J]. Energy and Buildings, 2002, 34(5) : 421-429.
  • 7Census and Statistics Department. Hong Kong Month ly Digest of Statistics [R], Hong Kong (1970-1996) .
  • 8Chan A L S, Development of guidelines for energy-efficient operation of fully air-conditioned builngs in Hong Kong [D]. city Univesity of Hong Kong , Hong Kong , 1994.
  • 9Baker N, Fanciotti A, Steemers K. Daylighting in architecture; a European reference book [M]. Comm of the European Communities, London: James and James (Sc. Publ.) ; 1993.
  • 10Hastings S R. Computer design tools for climate-responsive architecture [J]. Solar Wind Technology,1989, 6(4): 357-364.