期刊文献+

液相芯片技术及其临床应用 被引量:14

下载PDF
导出
摘要 液相芯片技术是一种利用混悬在液相中的分类编码微球作为反应及信号检测载体的检测技术,它充分利用发展成熟的流式细胞术检测原理,对临床大多数生物分子(如核酸、蛋白质等)进行高通量分析,目前已在研究和临床检测中得到了广泛的应用,现就其技术原理、特点及临床应用作简要介绍。
作者 何英 陆学东
出处 《国际检验医学杂志》 CAS 2006年第12期1107-1108,1111,共3页 International Journal of Laboratory Medicine
  • 相关文献

参考文献15

  • 1Nolan JP, Sklar LA, Suspension array technology: evolution of the flat-array paradigm, Trends Biotechnol, 2002, 20( 1) : 9-12.
  • 2Beske OE, Goldbard S, High-throughput cell analysis using multiplexed array technologies. Drug Discov Today,2002, 7(18 Suppl): S131-S135.
  • 3Vignali DA. Multiplexed particle-based flow cytometric assays. J Immunol Methods, 2000, 243(1-2):243-255.
  • 4Martins TB. Development of internal controls for the Lumlnex instrument as part of a multiplex seven-analyte viral respiratory antibody profile. Clin Diagn Lab Immunol, 2002, 9 ( 1 ):41-45.
  • 5Prabhakar U, Eirikis E, Miller B-E, et al. Multiplexed cytokine sandwich immunoassays: clinical applications. Methods Mol Med,2005, 114: 223-232.
  • 6de-Jager W, te-Velthuis H, Prakken BJ, et al, Simultaneous detection of 15 human cytokines in a single sample of stimulaled peripheral blood mononuclear cells, Clin Diagn Lab Immunol, 2003, 10(1): 133-139.
  • 7Morgan E, Varro R, Sepulveda H, et al. Cytometric bead array:a multiplexed assay platform with applications in various areas of biology. Clin Immunol0 2004, 110(3) : 252-266.
  • 8Martins TB, Pasi BM,Litwin CM, et al. Heterophile antibody interference in a multiplexed fluorescent microsphere immunoassay for quantitation of cytokineg in human serum. Clin Diagn Lab Immunol, 2004, 11(2): 325-329.
  • 9Martins TB, Burlingame R, von-Muhlen CA, et al. Evaluation of multiplexed fluorescent mierosphere immunoassay for detection of autoantibodies to nuclear antigens. Clin Diagn Lab Immunol,2004,11(6):1054-1059.
  • 10Yiannaki EE, Zintzaras E, Analatos A, et al, Evaluation of a microsphere-based flow cytometrie assay for diagnosis of celiac disease. J Immunoassay Immunochem, 2004, 25(4): 345-357.

二级参考文献4

  • 1Dunbar SA, Jacobson JW. Application of the luminex LabMAP in rapid screening for mutations in the cystic fibrosis transmembrane conductance regulator gene. A pilot study. Clin Chem,2000,46:1498-1500.
  • 2Weatherall DJ, Clegg JB. The thalassaemia syndromes. 4th ed. London:Blackwell Science Ltd, 2001. 250-251.
  • 3Earley MC, Vogt RF Jr, Shapiro HM, et al. Report from a workshop on multianalyte microsphere assays. Cytometry, 2002,50:239-242.
  • 4Smith PL, WalkerPeach CR, Fulton R J, et al. A rapid, sensitive, multiplexed assay for detection of viral nucleic acids using the FlowMetrix system. Clin Chem, 1998,44:2054-2056.

共引文献15

同被引文献132

引证文献14

二级引证文献40

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部