摘要
介绍了某化肥厂CO2压缩机中使用的28AT型干气密封装置和检测及控制系统,并针对其密封短期频繁失效的现象进行了故障分析,在此基础上提出了密封系统的改进方案和工艺调整措施,实施后取得了良好的效果,保障了该密封装置的可靠运行。
The 28AT dry gas seal set and its inspection and control system of the CO2 compressor in Jianfeng Fertilizer Factory were introduced. The reasons for the short term failure of the 28AT dry gas seal were analyzed and an improvement scheme of system and process adjustment measures were proposed. In terms of them the problems of frequent seal damage on the CO2 compressor were successfully solved and the normal and reliable operation of the seal, was insured.
出处
《流体机械》
CSCD
北大核心
2007年第1期41-45,共5页
Fluid Machinery