Application of Dynamic Linear Detecting Method in Data Processing of the Portable Blood Sugar Analyzer

Application of Dynamic Linear Detecting Method in Data Processing of the Portable Blood Sugar Analyzer
下载PDF
导出
摘要 In this paper,a dynamic linear detecting method,that the non-linear coefficient NL% was led and the non-linearity of data were estimated continuously and dynamically and determined when NL% exceeded reference value (5%),was used for data processing and could solve the problem caused by the phenomenon of substrate depleting occurred following the redox reaction in portable blood sugar analyzer.By contrast to the conventional end-point method,the dynamic linear detecting method is based on multipoint data collecting.Experiments of measuring the calibration glucose solution with 8 various concentrations from 50 mg/dl to 400 mg/dl were carried out with the analyzer developed by our group.The linear regression curve,whose correlation for the data was 0.9995 and the residual was 2.8080,were obtained.The obtained correlation,residual, and the computation workload are all fit for the portable blood sugar analyzer. In this paper, a dynamic linear detecting method, that the non-linear coefficient NL% was led and the non-linearity of data were estimated continuously and dynamically and determined when NL% exceeded reference value (5%), was used for data processing and could solve the problem caused by the phenomenon of substrate depleting occurred following the redox reaction in portable blood sugar analyzer. By contrast to the conventional end-point method, the dynamic linear detecting method is based on multipoint data collecting. Experiments of measuring the calibration glucose solution with 8 various concentrations from 50 mg/dl to 400 mg/dl were carried out with the analyzer developed by our group. The linear regression curve, whose correlation for the data was 0.9995 and the residual was 2.8080, were obtained. The obtained correlation, residual, and the computation workload are all fit for the portable blood sugar analyzer.
出处 《稀有金属材料与工程》 SCIE EI CAS CSCD 北大核心 2006年第A03期80-82,共3页 Rare Metal Materials and Engineering
关键词 data processing portable blood sugar analyzer dynamic linear detecting method data processing portable blood sugar analyzer dynamic linear detecting method
  • 相关文献

参考文献4

  • 1Lu Jianfeng. Dissertation[J], 2003, (2003): 5.
  • 2Carl D M, Julian I 1, Kamal Set al. Diabetes Care[J], 2002, 25(12): 2268.
  • 3Silverstein J H, Rosenbloom A L. ClinPediatr[J], 2000, 39: 257.
  • 4Tamada J A, Garg S, Jovanovic L et al. JAMA[J], 1999, 282: 1839.

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部