期刊文献+

离子选择性中性载体液膜光极的响应性能与液膜厚度 被引量:5

Relationship Between Response Characteristics and Membrane Thickness of Calcium Ion Selective Optode
下载PDF
导出
摘要 用钙离子光极探讨了中性载体液膜光极液膜厚度与其各主要响应性能的关系。结果表明光极的浓度线性响应范围与膜厚无关。在该范围内响应灵敏度(斜率)与膜厚成正比。响应时间t95则与膜厚度的平方成正比。响应速度与膜厚的平方成反比。光极的寿命与膜厚有正相关关系。在连续测定过程中,光极响应灵敏度以负指数形式下降,下降速率与膜厚成反比。 In this paper the relationship between the response characteristics and membrane thickness was investigated with a calcium ion selective optode based on ETH1001. Experimental results show that the membrane thickness of the optode is independent on its linear response range of concentration, but is directly proportional to the response sensitivity (slop) within the linear response range, and the 95%-response time varies directly with the square of membrane thickness. The speed of response is inversely proportional to the square of membrane thickness. The service time is positively correlated to the membrane thickness.During continuous determinations the response sensitifity decreases (vs. time) in negative exponential mode. The sensitivity decrease is inversely proportional to the membrane thickness.
出处 《分析化学》 SCIE EI CAS CSCD 北大核心 1996年第12期1417-1420,共4页 Chinese Journal of Analytical Chemistry
关键词 光极 分光光度法 液膜 钙离子 化学传感器 Optode, spectrophotometry, liquid membrane, calcium ion
  • 相关文献

同被引文献16

  • 1漆德瑶,孙为民.中性载体液膜离子选择性光极[J].化学传感器,1993,13(4):1-6. 被引量:1
  • 2章竹君,马望百.光导纤维化学传感器的新进展[J].分析试验室,1990,9(5):59-63. 被引量:5
  • 3彭吉虎 吴伯瑜.光纤技术与应用[M].北京理工大学出版社,1995,6..
  • 4雷肇棣.光纤通讯基础[M].西安:电子科技大学出版社,1997..
  • 5MORF W E, SEILER K, RUSTERHOLZ B, et al. Design of a novel calcium-selective optodes membranes based on neutral ionophore[J]. Analytical Chemistry, 1990,62(7) : 738.
  • 6SEILER K, SIMON W. Theoretical aspects of bulk optode membranes[J]. Analytica Chimica Acta, 1992,266(1) :73.
  • 7AMMANN D, OESCH U, BUHRER T, et al. Design of ion-ophores for ion-selective microsensors [J]. Canadian Journal of Physiology and Pharmacology, 1987,65 (5) : 879.
  • 8KHEZRI B, AMINI M K, FIROOZ A R. An optical chemical sensor for mercury ion based on 2-mercaptopyrimidine in PVC membrane[J]. Analytical and Bioanalytical Chemistry,2008, 390(7) : 1943.
  • 9KUSWANDI B, NURIMAN, DAM H H,et al. Development of a disposable mercury ion-selective optode based on trityl-picolinamide as ionophore[J]. Analytica Chimica Acta,2007, 591(2) :208.
  • 10CAP1TAN-VALLVEY L F, LAPRESTA-FERNANDEZ A, FERNANDEZ-RAMOS M D, et al. Establishment of wide-range linear response curves in bulk optode sensors for cations based on ion exchange [J]. Sensors and Actuators. B, Chemical, 2006,117(1) :27.