期刊文献+

Neuroform Ⅱ支架联合Matrix Ⅱ弹簧圈治疗颅内宽颈动脉瘤的初步经验 被引量:2

Combination of Neuroform Ⅱ stents and Matrix Ⅱ coils for embolization of wide-necked cerebral aneurysms: preliminary experience
下载PDF
导出
摘要 目的探讨Neuro{ormⅡ支架植入联合MatrixⅡ弹簧圈栓塞治疗颅内宽颈动脉瘤的疗效、技术要点、安全性及并发症防治。方法诊断为颅内宽颈动脉瘤的病人11例,其中大脑前动脉瘤2例,后交通动脉瘤4例,眼动脉瘤1例,大脑中动脉瘤2例,椎基底动脉瘤2例。7例先行NeuroformⅡ支架瘤颈成形,将微导管通过支架网眼置入动脉瘤内,填塞弹簧圈;4例先置入微导管于动脉瘤内,再释放支架后栓塞,术后3~6个月随访。结果所有病例栓塞操作均顺利完成,无手术并发症;其中致密填塞8例,部分致密填塞3例,术后病人均恢复良好,4例短期随访无再出血及血栓栓塞症状发生。结论NeuroformⅡ支架联合MatrixⅡ弹簧圈治疗颅内宽颈动脉瘤安全、有效。 Objective To investigate the efficacy, technical tip, safety and complication prevention of combining Neuro form Ⅱ stents and Matrix Ⅱ coils for wide-necked intracrenial aneurysms. Methods Among Ⅱ cases who were diagnosed with wide-necked intracranial aneurysms. Neuroform Ⅱ stents were released originally in 7 cases, then microcatheters were inserted into aneurysms through luminas of stnets and coils were implanted; Originally microcatheters were inserted into aneurysms, then Neuroform Ⅱ stents were released for embolism in 4 cases, the postoperative follow-up was from 3 to 6 months. Results All the operations were completed successfully. There were no complications in these cases. The aneurysms were packed totally in 8 cases and partly in 3 cases. Neither bleeding nor thrombus was found and the patients recovered well. Conclusion Combining Neuroform Ⅱ stents and Matrix Ⅱ coils for wide-necked intracrenial aneurysms is a safe and effective method.
出处 《中国介入影像与治疗学》 CSCD 2007年第1期23-26,共4页 Chinese Journal of Interventional Imaging and Therapy
关键词 动脉瘤 颅内 弹簧圈 支架 栓塞 Aneurysms, intracranial Coil Stents Embolization
  • 相关文献

参考文献8

  • 1Molyneux A,Kerr R,StrattonI,et al.International Subarachnoid Aneurysm Trial(ISAT)of neurosurgical clipping versus endovas-cular coiling in2143patients with ruptured intracranial aneu-rysms:a randomized trial[].The Lancet.2002
  • 2Broadbent LP,Moran CJ,Nehra A,et al.Transfer of a self-ex-panding stent to a braided microcatheter withthe aid of transcath-eter illumination:technical report andillustrative case[].American Journal of Neuroradiology.2003
  • 3Wanke I,Doerfler A,Schoch B,et al.Treat ment of wide-necked intracranial aneurysms with a self-expanding stent system:initial clinical experience[].American Journal of Neuroradiology.2003
  • 4Fiorella D,Albuquerque FC,Han P,et al.Preli minary experi-ence using the neuroformstent for the treat ment of cerebral anu-rysms[].Neurosurgery.2004
  • 5Chow MM,Woo HH,Masaryk TJ,et al.A novel endovascular treat ment of a wide-necked basilar apex aneurysm by using a Y-configuration,double-stent technique[].American Journal of Neuroradiology.2004
  • 6Howington JU,Hanel RA,Harrigan MR,et al.The neuroform stent,the first microcatheter delivered stent for use in the in-tracranial circulation[].Neuyosurgery.2004
  • 7Murayama Y,Tateshi ma S,Gonzalez NR,et al.Matrix and bioab-sorbable poly-meric coils accelerate healing of intracranial aneu-rysms:long-term experi mental study[].Stroke.2003
  • 8Wakhloo AK,Tio FO,Lieber BB,et al.Self-expanding nitinol stents in canine vertebral arteries:hemodynamics and tissue re-sponse[].American Journal of Neuroradiology.1995

同被引文献36

引证文献2

二级引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部