期刊文献+

容性负载谐振式DBD型臭氧发生器的供电电源 被引量:2

Research on DBD-type Ozone Generator Powered by Series Resonant Inventor in Capacitive Control
下载PDF
导出
摘要 为精确设计工业臭氧合成装置的供电电源,分析了容性控制下的全桥串联负载谐振式DBD型臭氧发生器供电电路的工作,通过结合电源开关器件的通断状况和DBD电路的放电、未放电状态,得出了整个电路在容性状况下的各个工作模态。推导了一系列等式,得出了臭氧发生器承受的最高电压、逆变电路工作频率和阻挡介质放电电路的放电功率显性表达式,分析了电路调节特性并进行了误差分析,结果验证了理论推导的正确性及工作在容性控制下的DBD供电电源具有频率波动小和控制方案易于实现的优点。 The DBD(Dielectric Barrier Discharge)type ozonier powered by full bridges series resonant inverter in capacitive control is studied in detail in the paper. By analyzing the on-off conditions of the power switches and the states of discharge and no discharge of DBD circuit, the working modes of power supply are achieved in capacitive control and some correlative expresses are deduced. Based on these expressions, the highest voltage of DBD circuit, the working frequency of inverter and the discharge power of DBD circuit are given. The error analysis of working frequency of inverter and the highest voltage of DBD circuit are made based on the theoretical calculations and experimental results. These expressions in the paper are validated by the results of error analysis. In addition, the regulating characteristics of power supply are analyzed. Compared with other control strategies, there are lots of merits in power supply for DBD circuit in capacitive control, such as small frequency fluctuating, big output power and being convenient for control and so on. The conclusions in the paper is helpful to designing the power supply powered by full bridges serial load resonant inverter for DBD type ozonier, and the analytic method of working modes in DBD circuit is suitable for other control strategies in serial load resonant power supply for DBD type ozonier.
出处 《高电压技术》 EI CAS CSCD 北大核心 2007年第2期46-49,共4页 High Voltage Engineering
关键词 容性控制 串联谐振 介质阻挡放电电路 臭氧发生器 模态分析 capacitive control serial resonant dielectric barrier discharge ( DBD) circuit ozonier modes analysis
  • 相关文献

参考文献14

二级参考文献62

  • 1白希尧,张宏.臭氧的发生及其应用研究[J].自然杂志,1991,14(11):813-817. 被引量:20
  • 2马虹斌,邱毓昌.高压臭氧发生器的研究与发展[J].电工电能新技术,1995,14(4):6-10. 被引量:18
  • 3张平,冯沛.IGBT应用中的过流保护[J].电力电子技术,1996,30(2):58-59. 被引量:19
  • 4徐小亮.[D].浙江大学,1997.
  • 5[1]Koudriavtsev O, Shengpei Wang, Nakaoka M. Power supply for silent discharge type load. IEEE Industry Applications Conference, 2000(1):581
  • 6远超公司.臭氧及其应用[M].长沙:湖南远超臭氧设备有限公司,2000.
  • 7Shengpei Wang, Nakaoka, Konishi. DSP based PDM and PWM type voltage fed load resonant inverter with high voltage tranaformer for silent discharge ozonizer [C]. Power Electronics Specialists Conference.New York: 29th Annual IEEE, 1998: 159-164.
  • 8Konishi, Shengpei Wang, Shirakawa, et al. Pulse density modulated high frequency load resonant inverter for ozonizer and its feasible performance evaluations[C]. Industry Applications Conference. Chicago:Thirty Third IAS Annual Meeting, 1998: 1313-1319.
  • 9Wang, Nakaoka , Konishi Y. PDM and PWM hybrid power control of a voltage source type high frequency inverter for ozonizer applications[C].Power Electronics and Variable Speed Drives. Detroit: Seventh International Conference,1998:40-45.
  • 10Wang, Konishi, Shirakawa, et al. Discrete pulse modulated high frequency soft switching inverter and its new application[C]. Power Electronics and Drive Systems. New York: [s. n.], 1999: 990-995.

共引文献140

同被引文献45

引证文献2

二级引证文献20