期刊文献+

自动电位滴定仪测定磁性材料1YC8中钴的测量不确定度评定 被引量:3

Evaluation of Uncertainty of Potentiometric Titration of Cobalt in Cobalt Alloy 1YC8 with an Auto-Titrator
下载PDF
导出
摘要 采用自动电位滴定仪测定磁性材料1YC8中钴含量,建立了测量过程分量的数学模型,分析了测量过程不确定度来源及各不确定度分量对总不确定度的影响,确定了测定结果的置信区间。给出磁性材料1YC8中钴的含量及其置信区间为10.92%±0.07%。 Cobalt in alloy of 1YC8 was determined potentiometrically with an Auto-titrator. Based on a comprehensive understanding of the whole procedure of the determination, mathematical model for evaluation of uncertainty in measurement was constructed and the sources of uncertainty and their effects on the total uncertainty were analyzed. On the base of the evaluated uncertainties of A type and/or B type, the combined standard uncertainty and finally the expanded or total uncertainty of the method were given. Result of cobalt in the alloy determined by the automatic potentiometric titration with its confidence interval was given as 10. 92%±0. 07 %.
作者 陈小军 刘虹
出处 《理化检验(化学分册)》 CAS CSCD 北大核心 2007年第2期132-134,共3页 Physical Testing and Chemical Analysis(Part B:Chemical Analysis)
关键词 测量不确定度 电位滴定法 置信区间 Uncertainty in measurement Cobalt Potentiometric titration Confidence interval
  • 相关文献

参考文献4

  • 1国家质量技术监督局计量司.测量不确定度评定与表示指南[M].北京:中国计量出版社,2000.29-44.
  • 2JJF 059--1999测量不确定度评定与表示[S].
  • 3中国实验室国家认可委员会.化学分析中不确定度的评估指南[M].北京:中国计量出版社,2002..
  • 4刘虹,杨胜喜,徐丽辉.ICP-AES法测定4J32膨胀合金中铜的不确定度分析[J].冶金分析,2003,23(3):45-47. 被引量:9

二级参考文献7

共引文献555

同被引文献95

引证文献3

二级引证文献12