摘要
对于通信交换局所用的大容量蓄电池(容量在2 000Ah/组以上),由于平时的维护不像基站小容量蓄电池方便,因此对大容量蓄电池的容量检查就显得更为重要。文中介绍了大容量蓄电池的容量测试方法,排查蓄电池电压损失的要因,并提出了相应的对策。
The battery in telecom exchanging bureau normally is high capacity (higher than 2 000Ah/Bank), which is not easy to be maintained as the smaller capacity battery in base stations. Therefore, it is more important to check and measure the capacity of those high capacity batteries. This paper describes the capacity measurement method of the high capacity battery and detection on the causes of voltage loss, and presents the corresponding resolution.
出处
《通信电源技术》
2007年第2期65-68,共4页
Telecom Power Technology
关键词
大容量蓄电池
电压损失
问题
high capacity battery
voltage loss
problem