期刊文献+

电站锅炉喷水减温系统热经济性分析 被引量:11

Economic Analysis of De-superheating Spray System Based on Thermal Economic State Equation
下载PDF
导出
摘要 以引进型300MW机组为例,运用现行热力系统热经济性状态方程定量分析了过热器和再热器喷水减温系统对机组热经济性的影响,指出过热器喷水减温由给水泵出口分流时对机组的经济性影响不大,在实际中可广泛采用;再热器喷水减温对机组经济性的影响比过热器喷水减温的影响要大得多,使机组的实际循环热效率降低较多,运行时应尽量减少或避免采用。 Taking introduced 300 MW generate sets for example, the effect on generating sets produced by superheater and re-heater de-superheating spray is analyzed by utilizing the thermo-economy system state equations. According to the digital analysis, the effect on generating sets of super-heater spray de-superheating when the water from feed pump is not strong, and the super-heater spray de-superheating may be widely used in practice. While the effect on generating sets of re-heater spray de-superheating is much stronger than the effect of super-heater spray de-superheating, and the thermal efficiency will decrease obviously. It is found that the use of re-heater spray desuperheating should be avoided during operation.
出处 《电力科学与工程》 2007年第1期66-68,共3页 Electric Power Science and Engineering
关键词 过热器 再热器 喷水减温 热经济性 super-heater re-heater de-superheating spray thermo-economy
  • 相关文献

参考文献6

二级参考文献16

  • 1张春发,丁常富,周健,李永华,范寒松.再热机组热经济分析的线性化方程[J].中国电力,1994,27(8):49-51. 被引量:11
  • 2林万超.火电厂热系统定量分析[M].西安:西安交通大学出版社,1985..
  • 3陈海平.火电厂热力系统热经济性在线监测系统的研究.华北电力大学硕士学位论文[M].,1995,11..
  • 4谭浩强,C程序设计,1994年
  • 5林万超,火电厂热系统定量分析,1985年,5页
  • 6陈海平,硕士学位论文,1995年
  • 7张春发,中国电力,1994年,1页
  • 8张春发,中国工程热物理学会工程热力学与能源利用学术会议论文集,2000年,298页
  • 9Zhang Chunfa,1999 Int Joint Power Generation Conference USAASME Power,1999年,497页
  • 10刘豹,系统工程导论,1987年