摘要 降低制冷温度至4 K温区是高频脉冲管制冷机的最新发展要求。本文介绍了一套热耦合型二级高频脉冲管制冷机的性能特性,它可以达到低于15 K以下的最低温度,是目前报道的高频二级脉冲管制冷机能获得的最低温度.通过对制冷机一级预冷、二级输入功率、二级冷量、室温条件等影响的分析,从实验角度揭示了该二级制冷系统的复杂影响,为进一步的深入分析和改进提供了基础。 Multi-stage version is the main method to reach the temperature below 20 K for high frequency pulse tube cryocoolers (HFPTC). This paper introduces the performance of a set of thermal-coupled version two stage HFPTC which could reach the temperature below 15 K, the reported lowest temperature for two stage HFPTC. Through the experimental analysis of first stage pre-cooling temperature, second stage input power, second stage cooling power, room temperature effect, the complex effects of this cooler are revealed for further analysis and improvement.
出处 《工程热物理学报》 EI CAS CSCD 北大核心 2006年第3期385-387,共3页 Journal of Engineering Thermophysics
基金 国家自然科学基金资助项目(No.50206025)
关键词 热耦合型二级高频脉冲管制冷机 性能 实验 thermal-coupled version two-stage HFPTC performance experiment
  • 相关文献

参考文献4

  • 1杨鲁伟.斯特林型高频脉冲管制冷机的现状与样机研制[J].低温与超导,2003,31(3):1-6. 被引量:15
  • 2Nast TC,Olson J,Evtumov B,et al.Development of a Two-Stage Pulse Tube Cryocooler for 35 K Cooling.Cryocoolers 12.New York,KA/PP,2003.213-218
  • 3Yang L,Thummes G.High Frequency Two-Stage Pulse Tube Cryocooler with Base Temperature Below 20 K.Cryogenics,2005,45(2):155-159
  • 4Olson J,Nast TC,Evtumov B,et al.Development of 10K Pulse Tube Cryocooler for Space Applications.Cryocoolers 12.New York:KA/PP,2003.241-246

二级参考文献11

  • 1边绍雄.小型低温制冷机[M].北京:机械工业出版社,1995..
  • 2Glaister D S, et al. An overview of the performance and maturity of long life cryocoolers for space applications, Cryocoolers 10,1999,1-- 19.
  • 3Radebaugh R, Pulse tube cryocoolers for cooling infrared sensors, Proceedings of SPIE, The international society for optical engineering, Infrared Technology and Applications XXVI, USA, 2000,363--379.
  • 4Chan C K, et al. Miniature pulse tube cooler, Proc. of the 7th. International Cryocooler. Conference, USA, 1992,113--124.
  • 5Kotsubo V, Olson J R, Nast T C, Development of a 2W at 60K pulse tube cryocooler for spaceborne operation, Cryocoolers 10, 1999,157--170.
  • 6Marquardt E D, Radebaugh R, Pulse tube oxygen liquefier, Advances in Cryogenic Engineering, 2000,45:457--464.
  • 7Hiratsuka Y, Kang Y M, et al. Development of a 5W at 80K Stirling pulse tube cryocooler, Advances in Cryogenic Engineering, 2000,45 : 57-- 63.
  • 8Kim S--Y, et al. Development of a 5W at 65K air--cooled pulse tube cryocooler, Cryocoolers11, 2001,125--129.
  • 9Charles I, Duval J M, Duband L, et al. High capacity pulse tube cryocooler, Cryocoolers12, 2003,131-- 138.
  • 10Liang J, Cai J H, Zhou Y, et al. Development of 40--80K linear--compressor driven pulse tube cryocoolers, Cryocoolersl2, 2003,115-- 121.