摘要
目的对预输血患者进行不规则抗体的筛查,降低和避免溶血性输血反应的发生。方法采用DiaMed IgG卡对17200例预输血患者标本进行不规则抗体筛查,不规则抗体阴性的标本用盐水交叉配血,而不规则抗体阳性的标本用DiaMed IgG卡进行交叉配血。结果不规则抗体筛查阳性59例,阳性率0.34%,59例抗体阳性的标本均用DiaMed IgG卡进行交叉配血,患者均输注了无相应抗原的红细胞。结论不规则抗体的筛查,能降低和避免溶血性输血反应的发生。
Objective In order to decrease or avoid hemolytic transfusion reaction, to screen irregular antibodies. Methods 17200 samples were detected with Diamed micro column IgG card, the negative samples crossmatch with saline; the positive samples crossmatch with DiaMed micro column IgG card. Results 59 samples were positive by detected and positive rate was 0.34% .Condusion Screening of irregular antibodies in patients serum can decrease or avoid hemolytic transfusion reaction.
出处
《四川医学》
CAS
2007年第4期363-364,共2页
Sichuan Medical Journal
关键词
溶血性输血反应
不规则抗体
hemolytic transfusion reaction
irregular antibodies