摘要
分析了由人工煤气转换成天然气后,原有雷诺式调压站出现的问题。提出了两种改造方案——对原雷诺式调压器进行改造及将雷诺式调压器更换成双薄膜式调压器,分析了两种改造方案的特点,给出了应用实例。
The problems existing in original Reynold gas regulator station converted from manufactured gas to natural gas are analyzed. The two kinds of reform schemes, including reform of original Reynold gas regulator and changing Reynold gas regulator into double diaphragm gas regulator, are put forward. The characteristics of the reform schemes are analyzed, and the application example is given.
出处
《煤气与热力》
2007年第4期7-9,共3页
Gas & Heat
关键词
雷诺式调压器
调压站
人工煤气
天然气
改造
Reynold gas regulator
regulator station
manufactured gas
natural gas