摘要
利用曝气生物滤池方法处理洗浴废水,研究了流量、气水比、容积负荷、水力停留时间、滤层高度对COD、LAS去除率的影响。研究结果表明:气水体积比为3∶1、BOD有机负荷为0.64 kg/(m.d)、COD容积负荷为2.0 kg/(m.d)时,COD去除率为81.40%,LAS去除率为92.34%,且出水水质稳定,符合生活杂用水标准。
Using biological aerated filter to treat bathing wastewater, the effects of flow, gas-water ratio, volume loading, HRT, height of filter on the removal rate of CODCr, LAS were studied. The results showed that: when the gas-water ratio was 3 : 1, the BOD organic loading was 0.64 kg/(m·d), the COD volume loading was 2.0 kg/ (m ·d), the removal rate of COD and LAS were 81.40% and 92.34% respectively, the quality of the enfluent water was stable, and met the requirement of Miscellaneous Domestic Water Quality Standard.
出处
《工业用水与废水》
CAS
2007年第2期30-32,共3页
Industrial Water & Wastewater
关键词
中水回用
洗浴废水
曝气生物滤池
陶粒
reclaimed water reuse
bathing wastewater
aeration biofilter
ceramsite