根据静水沉降颗粒分析法计算公式原理,分别采用了常用的密度计法和移液管法求取细颗粒土的粒径级配,分析了两种方法试验误差产生的原因,并证明密度计法较移液管法具有更简便、准确、节能的特点,建议尽量采用密度计法。
According to Principle of quiescent sedimentation granula analysis, the densimeter method and the piette method are used to get the size grading of fine-grain soil and the errors of two methods are analyzed. The test result shows that the densimeter method, compared to the piette method, is convenient, accurate and energy-conserving. Therefore, it is suggested that the former is used as far as possible.
出处
《土工基础》
2007年第2期79-81,共3页
Soil Engineering and Foundation
基金
湖南省科技计划重点项目(No.05FJ2006)
关键词
密度计法
移液管法
颗粒分析
densimeter method, piette method, granula analysis