期刊文献+

磷酸增敏离子选择性电极法测定痕量氟 被引量:1

Determination of trace fluoride by using phosphoric acid-sensitization ion-selective electrode method
下载PDF
导出
摘要 研究了以磷酸增敏、硝酸钠惰性电解质、柠檬酸三钠抗干扰的新体系总离子强度调节混合液(TISAP)中测定低含量氟的新离子选择性电极方法。方法线性范围为1.00×10-2~1.00×10-7mol/L,检出限为1.9ng/mL。该方法操作简便,检出限降低,平衡响应时间缩短,测定结果准确。应用到矿泉水、牛奶、酒中的痕量氟的测定,结果满意。 A ion - selective electrode method with a new TISAP solution in which phosphoric acid as a sensing reagent, sodium nitrate as inert electrolyte and sodium citric as anti - interference reagent for the determination of trace fluoride is developed. The linear range for the determination of fluoride is between 1.00 × 10^-2 - 1.00 × 10^ -7 mol/L, and the detection limit is 1.9 ng/mL. The proposed method has been applied to the determination of trace fluoride in mineral - water, milk and wine with satisfactory results.
出处 《化学传感器》 CAS 2007年第1期62-65,共4页 Chemical Sensors
关键词 磷酸增敏 离子选择性电极法 测定痕量氟 phosphoric acid - sensitized ion - selective electrode trace fluoride
  • 相关文献

参考文献6

  • 1Frant M S, Ross J W. Use of a total ionic strength adjustment buffer for electrode determination of fluoride in water supplies[J]. Anal Chem, 1968, 40(7), 1 169-1 171.
  • 2Fuchs C, Dorn D. Fluoride determination in plasma by ion selective electrodes: A simplified method for the clinical laboratory [J]. Clin Chim Acta, 1975, 60:157-167.
  • 3Ekstrand J A. micromethod for the determination of fluoride in blood plasma and saliva [J]. Calcif Tissue Res,1977, 23:225-228.
  • 4Villa A E. Rapid method for determing very low fluoride consentrations using an ion-selective electrode[J].Analyst, 1988, 113, 1 299-1 303.
  • 5张绍衡,李国童,高文秦.电化学分析法[M].重庆:重庆出版社,1993.61.
  • 6Van Staden J F, Vna Rensburg S D. Improvement on the microdiffusion technique for the determination of ionic and ionizable fluoride in cows' milk [J]. Analyst, 1991,116:807-811