在恒压控制系统设计过程中,侧重于从提高系统的可靠性和延长整机寿命角度出发,结合硬件特点,要求系统每次启动时将变频器按序分配给一台泵机,而其余泵机按照“先进先出”控制方式参与工频工作,在编程时通过建立和运算队列使上述思想得以实现.
It is emphasized on how to improve the system' s reliability and how to lengthen its work life while the constant pressure control system is designed. Based on the property of the hardwares, it is put forward that one pump is connected to the transducer in turn once the system starts to work and the other pumps connected to the standard industry power work by the "FIFO" rule. And the ideas above are realized by creatiny programs and operating some queues.