摘要 针对传统的差压流量计其安装位置对直管段长度要求较长,精确度随时间延长明显下降和维修工作量大等问题,阐述了威孔流量计的工作原理、结构和性能特征。其安装位置对直管段长度要求短、压损低、精确度高、维修量少,性能稳定,并介绍了应用情况。 For the problems in conventional differential pressure flow meters,for example,its installation location requires a long straight pipe section,the accuracy drops significantly with time,and large amount of maintenance work is involved,the working principle,construction and performance characteristics of V-cone flow meter are described.Its installation location involves shorter straight pipe section,low pressure loss,high accuracy,small amount of maintenance and stable performance.The application status is also introduced.
作者 胡嘉伟
出处 《硫磷设计与粉体工程》 2007年第3期20-23,共4页 Sulphur Phosphorus & Bulk Materials Handling Related Engineering
关键词 流量仪表 威孔流量计 原理 特性 应用 flow meters V-cone flow meter principle characteristic application