期刊文献+

脉冲调宽乘法器在交流应用下的误差及标准功率、电压、电流测量仪的研制 被引量:8

Errors of PWMM for AC Measuring and Research on Standard Power, Voltage, Current Measuring Instrument
下载PDF
导出
摘要 本文讨论了脉冲调宽乘法器用于交流测量时交直流变换误差与时分割频率的关系,提出了一种新的准确计算方法,并对相移误差等因素作了分析,给出了减小误差的措施。最后介绍了基于上述分析而设计研制的标准功率、电压、电流测量仪,其测量功率、电压、电流的误差均小于001% The relationship between the AC/DC transfer errors and the time division frequency when PWMM is applied to AC measurement is discussed in this paper. A new method of accurate calculation of errors is proposed and the factors of phase error ect. are analysed. The ways of reducing errors are also proposed. the design of the standard power, voltage, current measuring instrument based on above principles is introduced. The errors of the AC power, voltage, current measuring instrument are less than 0.01%.
出处 《计量学报》 CSCD 北大核心 1997年第1期50-56,62,共8页 Acta Metrologica Sinica
关键词 脉冲调宽乘法器 标准功率电 电流测量仪 Pulse width modulation multiplier AC/DC transfer errors AC measurement Standard power meter