摘要
文章针对磁力传动泵在应用中存在的故障进行分析,结合现场实际,对扭矩重新校核、部分结构改造和振动进行分析,实施后效果良好。
This article discusses the failure of magnetic force transmission pump in its application,and analyzes the recheck of torque,the partial structure modification and the vibration,which have good effect upon implementation.
出处
《石油化工设计》
CAS
2007年第2期25-26,29,共3页
Petrochemical Design
关键词
磁力泵
故障
改进
Magnetic-force transmission pump
Failure
Improvement