摘要 目的探讨蜗神经孔发育不良的多层螺旋 CT 表现。方法观察了50例100耳无中内耳疾患的正常人及9例10耳蜗神经孔发育不良患者蜗神经孔的 CT 特征,并在轴面图像上测量了蜗神经孔的横径值。结果正常组50例100耳均见筛孔区基底部骨性裂隙显示,蜗神经孔横径测量值为(2.32±0.25)mm。异常组9例10耳均表现为蜗神经孔狭窄,8耳筛孔区基底部骨性裂隙未显示;2耳筛孔区基底部骨性裂隙存在。合并内听道狭窄4例,前庭与水平半规管异常1例。异常组蜗神经孔经线测量结果:蜗神经孔横径最大1.5 mm,最小0.9 mm。结论蜗神经孔发育不良的典型CT 表现为蜗神经孔狭窄,筛孔区基底部骨性裂隙消失。蜗神经孔发育不良可能是耳蜗发育不良的一种亚型。 Objective To observe the CT findings of hypoplasia of cochlear nerve foramen. Methods CT findings of cochlear nerve foramen were observed in 50 volunteers ( 100 ears) and in 9 cases with hypoplasia of cochlear nerve foramen. The width of the bony canal for the cochlear nerve were measured in both groups. Results The fissure in the cribriform area were seen in every volunteers. The width of the bony canal for the cochlear nerve was (2. 32 ± 0. 25 ) mm in normal group. The stenosis of cochlear nerve foramen were shown in 9 cases ( 10 ears) ,the lacking of fissure in the cribriform area were seen in 8 ears, while the fissure were shown in 2 cases. The stenosis of internal auditory canal was shown in 4 cases. Abnormality of vestibule and horizontal semicircular canal was shown in one case. The maximum value of the width of the bony canal for the cochlear nerve was 1.5 mm, the minimum value was 0.9 mm. Conclusions The typical CT findings of hypoplasia of cochlear nerve foramen were stenosis of cochlear nerve foramen, the lacking of fissure in the cribriform area and cochlear nerve foramen without helix shape. The hypoplasia of cochlear nerve foramen may be a subtype of cochlear dysplasia.
出处 《中华放射学杂志》 CAS CSCD 北大核心 2007年第6期588-592,共5页 Chinese Journal of Radiology
关键词 耳蜗疾病 体层摄影术 X线计算机 Cochlear diseases Tomography, X-ray computed
  • 相关文献

参考文献9

  • 1Sennaroglu L, Saatci I. A new classification for cochleovestibular malformations. Laryngoscope ,2002,112:2230-2241.
  • 2Fatterpekar GM, Mukherji SK, Alley J, et al. Hypoplasia of the bony canal for the cochlear nerve in patients with congenital sensorineural hearing loss : initial observations. Radiology, 2000, 215:243-246.
  • 3何悦明,李铁一,杜铁桥,梁鸿儒,马新.慢性化脓性中耳炎的高分辨CT诊断价值[J].北京医学,2001,23(2):88-90. 被引量:32
  • 4巩若箴,晁宝婷,樊兆民,王海波.颞骨平行枕眶线多层螺旋CT扫描法及其价值[J].医学影像学杂志,2005,15(12):1049-1052. 被引量:12
  • 5巩若箴,柳澄,晁宝婷,陈青华,刘凯,武乐斌.砧骨发育不良的CT检查[J].医学影像学杂志,2004,14(7):533-535. 被引量:1
  • 6姜泗长.耳解剖学与颞骨组织病理学[M].北京:人民军医出版社,1995.160-160.
  • 7Casselman JW, Offeciers FE, Govaerts PJ, et al. Aplasia and hypoplasia of the vestibulocochlear nerve: diagnosis with MR imaging. Radiology, 1997,202:773-781.
  • 8Glastonbury CM, Davidson HC, Harnsberger HR, et al. Imaging findings of cochlear nerve deficiency. AJNR, 2002,23:635-643.
  • 9Nadol JB Jr, Xu WZ. Diameter of the cochlear nerve in deaf humans: implications for cochlear implantation. Ann Otol Rhinol Laryngol, 1992,101:988-993.

二级参考文献16

  • 1Phelps MD.High resdution CT of temporal bone:clinical ENT[J].Radiology,1993,18-19.
  • 2Turski P,Norman D,DeGroot J,et al.High-resolution CT of the petrous bone:direct vs.reformatted images[J].AJNR,1982,3:391-394.
  • 3Hermans R,Marchal G,Feenstra L,et al.Spiral CT of the temporal bone:value of image reconstruction at submillimetric table increments[J].Neuroradiology,1995,37:150-154.
  • 4Honda O,Johkoh T,Yamamoto S,et al.Comparison of quality of multiplanar reconstructions and direct coonal multidetector CT scans of the lung[J].Am J Roentgenol,2002,179:875-879.
  • 5Shinaver CN,Sandrasegaran K,Caldemeyer KS,et al.Ultrahigh-resolution spiral CT of the temporal bones using 0.5mm collimation (abstr)[J].Proceedings of the 35th Annual Meeting of the American Society of Neuroradiology Oak Brook,Ill:Amaerican Society of Neuroradiology,1997,57.
  • 6Mayo JR,Hartman TE,Lee KS,et al.CT of the chest:minimal tube current required for good image quality with the least radiation dose[J].AJR,1995,164:603-607.
  • 7Bernhardt TM,Rapp-bernhardt U,Fessel A,et al.CT scanning of the paranasal sinuses:axial helical CT with reconstruction in the coronal direction versus coronal helical CT[J].Br J Radiol,1998,71:846-851.
  • 8Hermans R, Marchal G, Feenstra L, et al. Spiral CT of the temporal bone:value of image reconstruction at submillimetric table increments[J].Neuroradiology,1995,37:150-154.
  • 9Henk W, Saffire SK, Piet GB, et al.Petrosal bone:coronal reconstructions from axial spiral CT data obtained with 0.5mm collimation can replace direct coronal sequential CT scans[J]. Radiology,1999,213:375-382.
  • 10Phoa SS, Venema HW, Majoie CB. High resolution CT imaging of the petrous bone: multiplanar reconstructions from dual slice helical CT with 0.5mm slice thickness can replace direct CT scanning (abstr)[J]. Radiology,1997,205:363.

共引文献41

同被引文献179

引证文献17

二级引证文献61

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部