摘要 接触氧化法处理效率高、耐冲击负荷、出水水质好、占地面积小。通过实验模拟研究了二段接触氧化工艺挂膜过程,实验结果表明:在水力停留时间是2 h,V(气):V(水)=20:1的条件下,挂膜15 d后COD的去除率达到81%,出水ρ(COD_G)达到70~92 mg·L^(-1);NH_3-N的去除率达到60%,出水ρ(NH_3-N)达到0.39~0.56 mg·L^(-1);SS的去除率达84%,出水ρ(SS)达到7.3 mg·L^(-1);COD,NH_3-N,SS的去除率受温度、来水水质的影响。 Two stage biological contact oxidation has many merits such as high treatment efficiency , high volume loading rate, well quality of effluent, smaller area, etc. The two stage biological contact biofilm was studied in this paper by simulation experiment. The results showed that after 15 days average CODc, NH3-N and SS removal rate were 81%, 60% and 84% respectively under the conditions of total air and water ratio 20:1 , HRT 2.0 h, and the p(CODcr), p(NH3-N) and p (SS) of outer-water were70 - 92 mg·L^-1, 0.39 - 0.56 mg·L^-1 and 7.3 mg·L^-1. CODcr, NH3-N and SS removal rate were effected by temperature and the input-water quality.
作者 陈俏波
机构地区 常州曙光化工厂
出处 《江苏环境科技》 2007年第A01期22-23,共2页
关键词 生活污水 挂膜 接触氧化 Domestic wastewater Biofilming Biological contact oxidation
  • 相关文献

参考文献6

二级参考文献43

  • 1陈国喜,周启星.恒液位推流式BSBR工艺工程设计及研究[J].应用基础与工程科学学报,2000,8(3):273-278. 被引量:13
  • 2岳舜琳.生物氧化在给水处理中的应用[J].中国给水排水,1996,12(4):17-20. 被引量:24
  • 3顾国维.水污染防治技术研究[M].上海:同济大学出版社,1997..
  • 4[4]Nedwell D B.Effect of low temperature on microbial growth:lowered affinity for substrates limits growth at low temperature[J].FEMS Microbiology Ecology,1999,30:101-111.
  • 5[5]Joost Groeneweg.Ammonia oxidation in nitrosomonas at NH3 concentrations near km:effects of pH and temperature[J].Wat Res 1994,28(12):2561-2566.
  • 6Chiemchaisri C,Wong Y K, Umse T, et al. Organic stabilization and nitrogen removal in a membrane separation bioreactor for domestic wastewater treatment[ J ]. Filtration & Separation, 1993, 30 (3) :247-252.
  • 7Butler D,Friedler E, Gatt K. Characterising the quantity and quality of domaestic wastewater inflows[J]. Waqter Science and Technology,1995,1 (7) : 13-24.
  • 8Orhon D, Ates E, Soma S, et al. Characterization and COD fractionation of domestic wastewaters[ J ]. Environmental Pollution,1997,95(2) : 191 -204.
  • 9Papaiaeovou I. Case study wastewater reuse in Limassol as an alternative water source[J]. Desalination, 2001,1389(1-3) : 55-59.
  • 10Gander M, Jefferson B, Judd S. Aerobic MBRs for dcanestic wastewater treatment: a review with cost considerations [ J ].Separation and Purification Technology, 2000,18 (2) : 119 - 130.

共引文献123

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部