新型调压式电压无功自动调节装置 被引量:4

Automatic Regulation Equipment of the New-type Voltage Adjustable Reactive Power
下载PDF
导出
摘要 分析了目前国内补偿设备的现状及存在的问题,提出了新的调节方式,即调节电容器端电压法调节电容器无功出力。并介绍了该装置的调节原理、设备构造、优点、运行效果,以及该装置的安装与调试。新型电压无功调节装置是一种最新的调节方式,他的研制,推广将对电压、无功调节领域产生重大影响。 This paper analyzes the present condition and existed problems of the domestic reactive power compensation equipment currently, the new-type voltage regulation method is proposed, i: e. regulating the end-voltage of the capacitor to regulate the reactive power output of the capacitor. This paper also introduces the principle, the the installation and commissioning of the equipment structure, the advantages, operation result and equipment. The regulation equipment of the new-type volt-age adjustable reactive power is a new kind equipment. The development and extension of such installation coil greatly affect on the voltage-reactive power regulation modes.
出处 《电力电容器》 2007年第3期9-12,51,共5页 Power Capacitors
关键词 调压法 电压无功 自动调节 Voltage regulating method Voltage-reactive Automatic regulation
  • 相关文献

参考文献2

  • 1GB12325-1990,电能质量供电电压允许偏差[S].
  • 2SD 325-1989,电力系统电压和无功电力技术导则[S].