期刊文献+

固定化曝气生物滤池处理污染河水的中试研究 被引量:9

Pilot-scale Study on Polluted River Water Treatment by G-BAF
下载PDF
导出
摘要 将功能化大孔载体(FPUFS)与复合微生物菌剂B350应用于曝气生物滤池而构成固定化曝气生物滤池(G-BAF),并开展了处理受污染河水的中试研究。装置在不同的水力停留时间(HRT)下连续运行了93 d,至试验后期,当系统的HRT为2 h时,对浊度、CODMn、NH4+-N和TP的平均去除率分别为93.4%、55.6%、95.8%和71.5%,出水水质达到了《地表水环境质量标准》(GB 3838—2002)的Ⅲ类标准。环境扫描电镜(ESEM)与气相色谱/质谱(GC/MS)的分析结果表明:G-BAF中的载体表面附着了大量球菌、杆菌以及多种形态的原、后生动物,这增强了对氮、磷以及难降解有机物的去除效果。 The macroporous carrier FPUFS and special microorganisms (B350) were used in a biological aerated filter (BAF) to form a Gaia-BAF (G-BAF) and treat polluted river water. The system was continuously operated for 93 days at different hydraulic retention time (HRT). In the later experimental stage, when HRT is 2 h, the average removal rates of turbidity, CODMn, NH4^+ - N and TP are 93.4%, 55.6% , 95.8% and 71.5% respectively. The effluent quality can reach the grade Ⅲ of Environmental Quality Standards for Surface Water ( GB 3838 - 2002). The results of ESEM and GC/MS show that there are lots of cocci, bacilli, protozoan and metazoan species immobilized on the surface of carriers, which can enhance the removal effect of nitrogen, phosphorus and refractory organic compounds.
出处 《中国给水排水》 CAS CSCD 北大核心 2007年第13期20-23,共4页 China Water & Wastewater
基金 国家高技术研究发展计划(863)项目(2003AA601010)
关键词 污染河水 固定化曝气生物滤池 环境扫描电镜 气相色谱/质谱 polluted river water G-BAF ESEM GC/MS
  • 相关文献

参考文献10

二级参考文献91

共引文献1596

同被引文献165

引证文献9

二级引证文献41

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部