期刊文献+

甲基异丁基甲酮对电感耦合等离子体发射光谱分析的影响

Effects of MIBK on ICP Emission Spectral Analysis
下载PDF
导出
摘要 研究了ICP(电感耦合等离子体Inductively Coupled Plasma)中甲基异丁基甲酮对试液物理性质(表面张力、粘度)及雾化特性的影响,观测了发射强度和信背比及阳流和栅流随加入浓度变化的关系,并且用ICP发射光谱法测定了自来水中的Pb元素。结果表明,试液物理性质的改变使雾化效率提高了,光谱强度增强了。用该方法对自来水样品中Pb元素的测定结果平均值为1.933*10-3mg/L,RSD为3.87%,回收率为107%。 The effects of MIBK on the physical properties ( surface tension, viscosity) and nebulization of sample solution in the ICP were investigated. The relation of emission intensity, signal - to - background ratio, anode current, and grid current with concentration were observed. The elements of Pb in tap water were determined by ICP - AES. The experimental results showed that the change in physical properties of sample solution led to the improvement of efficiency of nebulizer and the increase of line intensity. The determined average result of Pb in tap water was 1. 933 * 10^-3 mg/L, RSD 3.87%. Recoveries of Pb was 107%.
出处 《现代科学仪器》 2007年第3期104-106,共3页 Modern Scientific Instruments
基金 河北省科技厅攻关项目(02820180D)资助
关键词 ICP 甲基异丁基甲酮 物理性质 雾化特性 ICP MIBK physical property nebulization
  • 相关文献

参考文献13

  • 1S. E. Long, R. D. Snook. Some observation on electrothermal vaporisation for sample introduction into the inductively coupled plasma. Spectrechimica Acta. ,1985,40B(4) :553 -568
  • 2John W. Novak, Jr., Richard F. Browner. Characterization of droplet sprays produced by pneumatic nebulizers. Anal. chem. ,1980,52(6) :792 -796
  • 3He Zhi - zhuang, and R. M. Barnes. Recycling nebulizing system for millili- ter volume samples with inductively coupled plasma spectrometry. Spectrochim. Acta. , 1985,40B (1/2) : 11 - 19
  • 4Chen Bin,Zhuang Zhi - xia,Wang Xiao - ru,et al. A novd sample introduction technique for the simultaneous determination of As, Se, Ge and Hg in Chinese medicinal material. Chemical Research in Chinese Universities, 2001,17(4) :400 -406
  • 5J. C. Iivaldi, J. Vollmer, W. Slavin. The conespray nebulizer for inductively coupled plasma atomic emission spectrometry. Spectrochim. Acta. , 1991, 46B(6/7 ) : 1063 - 1072
  • 6Jose L. Todoli, Jean M. Mermet. Elemental analysis of liquid microsamples through inductively coupled plasma spectrochemistry. Trends in Analytical Chemistry ,2005,24(2) : 107 - 116
  • 7G. Schaldach,L. Berger, I. Razilov, et al. Characterization of a double - pass spray chamber for ICP spectrometry by computer simulation (CFD). Sperctrochim. Acta. ,2002,57B(10) : 1505 - 1520
  • 8Ari Vaianen, Reijo S. , Jaune S. and Jukka R.. Ultrasound - assisted ex- tration in the determination of arsenic, cadmium,lead, and silver in contaminated soil samples by inductively coupled plasma atomic emission spectrometry. Anal. Bioanal. Chem. ,2002, 373(3) : 93 -97
  • 9S. W. Mcgeorge and E. D. Salin. The effect of integration time and interval on precision with three pneumatic nebu lizers used for inductively coupled plasma atomic emission spectrometry. Appl. Spectrosc, 1985, 39(6) : 989 -993
  • 10M. T. Cicerone, P. B. Farnsworth. A simple, non - invasive method for the measurement of gas flow velocities in the inductively coupled plasma. Sperctrchim. Acta. , 1989,44B(9) :897 - 907

共引文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部