摘要 建立了用电感耦合等离子体原子发射光谱法(ICP-AES)测定钛酸钡中游离钡含量的方法。比较了硝酸和乙酸溶样分离游离钡的效果,结果表明,φ=10%的乙酸作为溶剂效果较好。考察了Ba的分析谱线和共存元素干扰问题,Ti对Ba 233.527 nm的测定不产生干扰。标准溶液中加入了与样品量一致的乙酸,保持分析介质的一致性。工作曲线的线性方程为Y =4.219 6 X+0.307 3,方法的线性范围为0.01~100 mg/L,检出限是0.004 mg/L。用于钛酸钡样品的测定,相对标准偏差为1.58%,加标回收率为96.3%~104.0%,测定结果与ED- TA滴定法对照,吻合较好。 Inductively coupled plasma-atomic emission spectrometry(ICP-AES)was used for the determination of dissociative barium content in the BaTiO3. It was shown experimentally that when acetic acid (φ= 10%)was used as solvent to dissolve sample, its dessolvability was better than HNO3. The interference of the coexisting elements on the barium analytical line were also investigated and the results show that Ti has no interference on the Ba line (233. 527 nm). Acetic acid of same concentration was added into the standard solution to keep the medium consistent with the sample solution. The linear equation of the calibration curve is Y:4. 219 6X+0. 307 3 with the linear range of 0.01-100 mg/L and detection limit of 0. 004 mg/L for barium. The method has been used to determine dissociative barium in the barium titanate sample,giving relative standard deviation(RSD) of 1.58% and the recovery of 96.3%-104. 0%. The results were in good consistent with those obtained by EDTA titration.
出处 《冶金分析》 EI CAS CSCD 北大核心 2007年第6期70-72,共3页 Metallurgical Analysis
关键词 电感耦合等离子体原子发射光谱法(ICP-AES) 钛酸钡 游离钡 inductively coupled plasma-atomic emission spectrometry barium titanate dissociative barium
  • 相关文献

参考文献6

二级参考文献1

  • 1D Henngs. Solid State Chemistry[J], 1978, (26) :329.

共引文献16

同被引文献13

  • 1杜保安,杨玉华,李正平.电感耦合等离子体发射光谱法定量测试明胶中的微量金属元素Hg和Rh——应用MSF模型改进Hg结果的精密度和检测限[J].光谱学与光谱分析,2006,26(1):140-143. 被引量:11
  • 2胡述戈.微波消解-电感耦合等离子体原子发射光谱法测定铁矿石中8种成分[J].冶金分析,2006,26(6):40-43. 被引量:23
  • 3北京矿冶研究总院分析室.矿石及有色金属分析法[M].北京:科学出版社,1973.
  • 4GB/T 15076.2-94钽铌化学分析方法:钽中铌量的测定[S].
  • 5JIS H 1689-1976钽中铌的测定方法[A].
  • 6Karbasi MH,Jahanparast B,Shamsipur M,et al.Simultaneous trace multielement determination by ICP-OES after solid phase extraction with modified octadecyl silica gel[J].Journal of Hazardous Material,2009,170(1):151-155.
  • 7Froes R E S,Neto W B,Naveira R L P,et al.Exploratory analysis and inductively coupled plasma optical emission spectrometry(ICP-OES)applied in the determination of metals in soft drinks[J].Microchemi.,2009,92(1):68-72.
  • 8Gonzalvez A,Armenta S,De La Guardia M.Trace elemental composition of curry by inductively coupled plasma optical emission spectrometry(ICP-OES)[J].Food Addttive s&Contaminants:Part B Surveillance,2008,1(2):114-121.
  • 9Rabb S A,Winchester M R,Yu L L.Accurate determinations of Ge atom fractions in SiGe semiconductor chips using high performance ICP-OES[J].J.Anal.At.Spectrom.,2008,23(4):550-554.
  • 10Raven K P,Reynolds J W,Loeppert R H.Trace element analyses of fertilizers and soil amendments by axial-view inductively-coupled plasma atomic emission spectrophotometry[J].Communications in Soll Science and Plant Analysis,1997,28(3-5):237-257.

引证文献1

二级引证文献8

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部