摘要
对采用红外监测反推法,由加热圆柱外壁温度,确定圆柱体内壁温度的误差进行了量化分析。在分析的基础上,给出了影响圆柱体内壁温度测量的主要因素,提出了优化加热柱体内壁温度测量的途径。基于上述分析,给出了一种适时调控的温度测量解决方案。
It is given that quantitative diagnosis to estimation errors of internal temperature of a hot wire embedded at the center of a cylinder-shaped heat equipment. The methods of optimization are developed for the quantitative diagnosis by solving an inverse heat condition problem based on infrared temperature-measuring. After that, a case of control is designed based on the diagnosis above.
出处
《激光与红外》
CAS
CSCD
北大核心
2007年第7期656-657,660,共3页
Laser & Infrared
基金
江苏技术与经济管理委员会立项项目(06JC043)
江苏高校自然科技基金项目(07KJB510066)
关键词
红外测温
加热圆柱体
误差分析
优化方法
infrared temperature-measuring
heated cylinder
estimation errors
optimization method