期刊文献+

SPR生物传感器在乳品工业中的应用 被引量:2

Applications of SPR biosensor in dairy industry
下载PDF
导出
摘要 介绍了SPR的概念和SPR生物传感器基本原理,并从监测乳牛发情,检测乳品抗生素残留,检测乳品脂肪含量,检测乳品微生物污染和检测乳品掺假成分这5个方面综述SPR生物传感器在乳品工业中的应用及发展前景。 The article introduced the conception of SPR and the basic principle of SPR biosensor, the application and prospect of SPR biosensot in dairy industry are reviewed in five aspects of monitoring the empathema of dairy cows, detecting the residual of antibiotic, the content of fat in the milk, the contamination of dairy microorganism and the content of dairy sophistication.
出处 《中国乳品工业》 CAS 北大核心 2007年第7期37-39,共3页 China Dairy Industry
关键词 SPR 生物传感器 乳品工业 SPIL biosensor dairy industry
  • 相关文献

参考文献13

  • 1牟颖,张寒琦,金钦汉.表面等离子体子共振技术及其在生命科学中的应用[J].现代科学仪器,2001,18(2):27-32. 被引量:11
  • 2裴仁军,汪尔康,杨秀荣.表面等离子体共振免疫传感的放大检测研究[J].北京大学学报(自然科学版),2001,37(2):186-191. 被引量:7
  • 3司土辉.生物传感器[M].北京:化学工业出版社,2003:20-24.
  • 4DISKIN M G,SREENAN J M.Expression and Detection of Oestrus in Cattle[J].Reprod Nutr Dev,2000,40:481-491.
  • 5WALDMANN A.Monoelonal Antibodies to Progesterone.Characterization and Selection for Enzyme Immunoassay in Bovine Milk[J].Hybridoma,1999,18(3):289-296.
  • 6ELS H G,JAMES P G,JOSEPH M S,et al.Development and Validation of a Biosensor-Based Immunoassay for Progesterone in Bovine Milk[J].Journal of Immunological Methods,2002,267:131-138.
  • 7EVA G.SPR Biosensor Analysis of-Lactam Antibiotics in Milk[D].Doctoral Thesis,2003.
  • 8李延华,张兰威,王伟君.国标TTC法与AOAC纸片法检测乳中-β内酰胺类抗生素残留对比研究[J].中国乳品工业,2006,34(5):57-59. 被引量:9
  • 9FERGUSON J P,BAXTER G A,MCEVOY J D G,et al.Detection of Streptomycin and Dihydrostreptomycin Residues in Milk,Honey and Meat Samples Using an Optical Biosensor[J].Analyst,2002(127):951-956.
  • 10CACCIATORE G,PETZ M,RACHID S,et al.Development of an Optical Biosensor Assay for Detection of Lactam Antibioticsin Milk Using the Penicillin-Binding Protein 2x[J].Analytica Chimica Acta,2004 (520):105-115.

二级参考文献49

  • 1汪洛,陶祖莱.表面等离子体激元共振与生物分子相互作用分析[J].生物化学与生物物理进展,1996,23(6):483-487. 被引量:9
  • 2杨延彬.实用免疫学[M].长春:长春出版社,1994.424.
  • 3INDYK H E, PERSSON B S,CASELUNGHE M C. Determination of Vitamin B12 in Milk Products and Selected Foods by Optical Biosensor Protein-Binding Assay Method Comparison[J]. J AOAC Int, 2002,85(1):72-81.
  • 4RASSOOLY A. Surface Plasmon Analysis of Sraphylococcal Enterotoxin B in Food[J].J Food Prob,2001,64(1):37-43.
  • 5RICH R L, MYSZKA D G, BIACORE J. A New Platform for Routine Biomolecular Interaction Analysis[J].Journal of Molecular Recognition,2001,14:223-228.
  • 6RICH R L,MYSZKA D G.Advances in Surface Plasmon Resonance Biosensor Analysis[J].Current Opinion in Biotechnology,2000,11(1):54-61.
  • 7RICH R L,MYSZKA D G .Survey of the Year 2000 Commercial Optical Biosensor Literature[J].Journal of Molecular Recognition,2001,14:273-294.
  • 8孟昭赫.食品卫生检验方法注释(微生物学部分)[M].北京:人民卫生出版,1996.836-850.
  • 9Meeten G H and North A N. Refractive index measurement of absorbing and turbid fluids by reflection near critical angle[ J]. Meas Sci Technol, 1995,6:214-221.
  • 10Mohammadi M. Colloidal refractometry: meaning and measurement of refractive index for dispersions ; the science that time forgot[ J]. Adv Coil Interf Sci, 1995,62 : 17-29.

共引文献44

同被引文献38

引证文献2

二级引证文献11

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部