摘要 本文简要介绍了近年来SPECT准直器几何设计和对应图像重建计算方法的最新进展以及当前图像重建研究的一些热点。 In this short note we give a brief introduction to the recent development in the design of SPECT collimator geometry and its corresponding reconstruction algorithms. Moreover, we review some hot fields of recent studies on SPECT image reconstruction problem. (
出处 《核电子学与探测技术》 CAS CSCD 北大核心 1997年第3期221-224,共4页 Nuclear Electronics & Detection Technology
基金 国家自然科学基金
关键词 准直器 逆变换 重建算法 图像重建 核电子仪器 Collimator Radon inversion formula Reconstruction algorithm)
  • 相关文献

参考文献8

  • 1Zeng G L,IEEE Trans Med Imag,1994年,13卷,549页
  • 2Cao Z,Phys Med Biol,1994年,39卷,281页
  • 3Wu Chunwu,博士学位论文,1994年
  • 4Zeng G L,IEEE Trans Med Imag,1993年,12卷,575页
  • 5尤江生,IEEE Trans Med Imag
  • 6尤江生,A harmonic decomposition reconstruction algorithm for spatially varying focal length collimators
  • 7Weng Y,Analytical inversion formula for uniformly attenuated fan-beam projections
  • 8尤江生,Correction of nonuniformity in convolution backprojection slgorithm for fan-beam geometry

同被引文献11

  • 1GROCH M W,ERWIN W D. SPECT in the year 2000:Basic principles[J].Journal of Nuclear Medicine Technology,2000,(04):233-244.
  • 2YANG Y W,CHEN J C,CHANG C J. Evaluation of collimator choice and scatter correction on 123I SPECT images[J].Nuclear Instruments and Methods in Physics Research A:Accelerators,Spectrometers,Detectors and Associated Equipment,2008.204-211.
  • 3HRUSKA C B,O' CONNOR M K. Effect of collimator selection on tumor detection for dedicated nuclear breast imaging systems[J].IEEE Transactions on Nuclear Science,2006,(05):2680-2689.doi:10.1109/TNS.2006.879824.
  • 4CAO Z X,BAL G,ACCORSI R. Optimal number of pinholes in multi-pinhole SPECT for mouse brain imaging:A simulation study[J].Physics in Medicine and Biology,2005.4609-4624.
  • 5MAHMOOD S T,ERLANDSSON K,CULLUM I. Design of a novel slit-slat collimator system for SPECT imaging of the human brain[J].Physics in Medicine and Biology,2009.3433-3449.
  • 6VUNCKX K,BEQU D,DEFRISE M. Single and multipinhole collimator design evaluation method for small animal SPECT[J].IEEE Transactions on Medical Imaging,2008,(01):36-46.doi:10.1109/TMI.2007.902802.
  • 7MAHMOOD S T,ERLANDSSON K,CULLUM I. The potential for mixed multiplexed and non-multiplexed data to improve the reconstruction quality of a multi-slit-slat collimator SPECT system[J].Physics in Medicine and Biology,2010.2247-2268.
  • 8HARUTA N,OGAWA K. Evaluation of iterative methods for aperture correction in SPECT[J].Sys Comput Japan,2005,(02):23-32.
  • 9凌松云,曹文田,包尚联.OSEM重建算法中几个关键问题的研究[J].中国医学物理学杂志,2008,25(4):729-736. 被引量:2
  • 10代秋声,漆玉金.高分辨针孔SPECT三维图像重建的实现[J].原子能科学技术,2009,43(11):1034-1038. 被引量:2

引证文献1

二级引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部