摘要 腰椎间盘手术是骨科领域内一种常见手术,无论是开放手术还是微创手术,都有可能出现神经根或马尾神经的损伤,2002年11月-2006年4月,我院采用小切口技术和后路内窥镜下椎间盘切除术(microendoscopic discectomy,MED)共完成腰椎间盘突出症髓核切除术540例.其中出现4例神经损伤,报告如下。
作者 李时军
出处 《中国脊柱脊髓杂志》 CAS CSCD 2007年第8期638-639,共2页 Chinese Journal of Spine and Spinal Cord
  • 相关文献

参考文献4

二级参考文献13

  • 1张绍东,唐天驷,吴小涛,杨惠林,孙俊英,邱勇,谭远超.腰椎椎间融合器的翻修手术[J].中华骨科杂志,2004,24(9):530-533. 被引量:21
  • 2Kuslich SD,Ulstrom CL,Friffith SL,et al.The Bagby and Kuslich method of lumbar interbody fusion:history,techniques,and 2-year follow-up results of a United States prospective,multi-center trial[J].Spine,1998,23 (11):1267-1279.
  • 3Brantigan JW,Steffee AD,Lewis ML,et al.Lumbar interbody fusion using the Brantigan I/F cage for posterior lumbar interbody fusion and variable pedicle screw placement system:two-year results from a Food and Drug Administration investigational device exemption clinical trial[J].Spine,2000,25(12):1437-1446.
  • 4Wong HK,Goh JC,Goh PS.Paired cylindrical interbody cage fit and facetectomy in posterior lumbar interbody fusion in an Asian population[J].Spine,2001,26(5):572-577.
  • 5Hodges SD,Humphreys SC,Eck JC,et al.Intraoperative loosening of Bagby and Kuslich cages during anterior lumbar interbody fusion[J].J Spinal Disord,2000,13(6):535-537.
  • 6Kuslich SD,Danielson G,Dowdle JD,et al.Four-year followup results of lumbar spine arthrodesis using the Bagby and Kuslich lumbar fusion cage[J].Spine,2000,25(20):2656-2662.
  • 7Nakano M,Matsui H,Miaki K,et al.Postolaminectomy adhersion of the cauda equina:changes of postoperative vascular permeability of the equina in rats[J].Spine,1997,22(10):1105-1114.
  • 8Lund T,Oxland TR,Jost B,et al.Interbody cage stabilization in the lumbar spine:biomechanical evaluation of cage design,posterior instrumentation and bone density[J].J Bone Joint Surg (Br),1998,80(2):351-359.
  • 9Oxland TR,Hoffer Z,Nydegger T,et al.A comparative biomechanical investigation of anterior lumbar interbody cages:central and bilateral approaches[J].J Bone Joint Surg (Am),2000,83(3):383-393.
  • 10Pitzen T,Geisler FH,Matthis D,et al.Motion of threaded cages in posterior lumbar interbody fusion[J].Eur Spine J,2000,9(6):571-576.

共引文献30

同被引文献24

引证文献6

二级引证文献4

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部