高锰酸钾滴定法测定补钙制品中的钙含量 被引量:17

Determination of Calcium Content in Calcium Supplementation Products by Potassium Permanganate Titrimetric Method
下载PDF
导出
摘要 [目的]为了准确测定补钙制品中的钙含量。[方法]建立了高锰酸钾容量滴定法测定补钙制品中钙含量的方法。[结果]该法是在含有EDTA的pH值为3.5 ̄4.5的氨性溶液中,先用草酸盐选择性地沉淀钙离子。沉淀物经过滤、洗涤后,用稀硫酸将所得草酸钙沉淀物溶解,然后在75 ̄85℃条件下用高锰酸钾标准溶液滴定。测定结果的相对标准偏差(RSD)为0.30%(n=5),回收率(R)在96.30% ̄101.12%。[结论]用高锰酸钾滴定法测定补钙制品中的钙含量,简单、快捷,准确、干扰小。 [Objective] The study aimed to determine the calcium content in calcium supplementation products exactly. [Method] The method of determining the calcium content in calcium supplementation products by potassium permanganate titrimetric method was established. [Result] By the method, the calcium ion was deposited by oxalate in selectivity in ammonia solution (pH 3.5-4.5) with EDTA. After the sediment was filtrated and washed, the calcium oxalate sediment was dissolved by diluted sulfuric acid, then titrated by potassium permanganate standard solution at 75-85 ℃. The relative standard deviation of determination result was 0.30 %(n=5 ), with the recovery rate of 96.30 %-101.12 %. [Conclusion] The method of determining the calcium content in calcium supplementation products by potassium permanganate titrimetric method was simple, rapid, exact and small in disturbances.
作者 加建斌
出处 《安徽农业科学》 CAS 北大核心 2007年第23期7076-7077,共2页 Journal of Anhui Agricultural Sciences
关键词 高锰酸钾滴定法 钙制品 钙含量 Potassium permanganate titrimetric method Calcium products Calcium content
  • 相关文献

参考文献6

二级参考文献6

  • 1杨慧芬 白德美.食品卫生理化检验标准手册[M].北京:中国标准出版社出版,1997.183-184.
  • 2陆合 张宏陶.生活饮用水标准检验方法注解[M].重庆:重庆大学出版,1993.60-61.
  • 3GB/TS009.92—2003.食品卫生检验方法理化部分(一)[S].
  • 4中国食品工业标准汇编.食品添加剂卷(中)[M].北京:中国标准出版社,2002.221.
  • 5GB/T13025—91.制盐工业通用试验方法钙和镁离子的测定[S].
  • 6刘守廷,罗平,谢涛,蒋天成,莫达松,张兰.EDTA作基体改进剂火焰原子吸收法直接测定植酸中钙[J].理化检验(化学分册),1998,34(11):517-518. 被引量:4

共引文献249

同被引文献140

引证文献17

二级引证文献73

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部