模拟定位便携式可移动激光灯的临床设计

Clinical design of protable and moveable laser light for simulation immobilization
下载PDF
导出
摘要 目的:介绍模拟定位用便携式可移动激光灯的临床设计。方法:利用现有材料如π型尺、柱形激光灯等,根据激光定位系统的原理自行设计此装置,经安装、调试后用于临床。结果:该装置配合CT扫描机进行患者定位,替代了昂贵的激光定位系统,操作简单,使用方便。结论:该装置材料及制作比较粗糙,有待于改进,以确保定位精度。 Objective To introduce the clinical design of the portable and moveable laser light for simulation immobilization. Methods According to the theory of the laser immobilization system, the setting is designed by using current material, such as a ruler of π-shape and pillar-shape laser light etc. After installation and adjustment, it is used in clinic. Results Patient can be immobilized by CT and this setting, Being simple to operate and convenient to use, this setting can act for the expensive laser position system. Conclusion The material and creation of this setting are rougher, so it needs improvement to insure the accuracy of position.
机构地区 解放军第
出处 《医疗卫生装备》 CAS 2007年第8期77-77,80,共2页 Chinese Medical Equipment Journal
关键词 模拟定位 便携 激光灯 simulated immobilization portable moveable laser light
  • 相关文献

参考文献2

二级参考文献18

  • 1[1]AAPM.AAPM report No.83.Quality assurance for computed-tomography simulators and the computed-tomographysimulation process[J].Med Phys,2003,30:2762-2792.
  • 2[2]Curry TS,Dawdey JE,Murry RC.Christensen's physics of diagnostic radiology [M].4th ed.PA,Malvern:Lea & Febiger,1990.
  • 3[3]Cozzi L,Fogliata A,Buffa F.Dosimetric impact of computed tomography calibration on a commercial treatment planning system for external radiation therapy [J].Radiother Oncol,1998,48:335-338.
  • 4[4]Williams TR,Thwaites TI.Radiotherapy physics in practice [M].2nd ed.Oxford:Oxford University press,2000.118-149.
  • 5[5]Constantinouc,Harrington JC,DeWerd LA.An electron density calibration phantom for CT-based treatment planning computers [J].Med Phys,1992,19(2):325-332.
  • 6[6]Cozzi L,Fogliata A,Buffa F,et al.Dosimetric impact of computed tomography calibration on a commercial treatment planning system for external radiation therapy [J].Radiother Oncol,1998,48:335-338.
  • 7[7]Beneventis,Chionne F,Gobbi G,et al.Quantitative CT to mography for radiotherapy treatment planning:calibration phantom and sources of error[J].Radiother Oncol,1995,37 (Suppl):41.
  • 8[8]NCRP.NCRP Report No.99.Quality assurance for diagnostic imaging equipment [R].Bathesda MD:National Councilon Radiation Protection and Measurements,1988.
  • 9[10]Nagata Y,Nishidai Ade M,CT simulator:a new 3-D planning and simulating system for radiotherapy [J].Int J Radiat Oncol Biol Phys,1990,18:505-518.
  • 10[11]Sherouse G,Mosher KL,Novins K,et al.Virtual simulation:concept and implementation [A].Bruinvis LAD.North-Holland:Ninth International Conference on the Use of Computers in Radiation Therapy [C].1987.433-436.

共引文献32

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部