期刊文献+

磁共振三维动态增强技术参数对血管成像质量的影响 被引量:2

The evaluation of the effect of 3D dynamic contrast enhancement MRA technical parameter on image quality
下载PDF
导出
摘要 目的:探讨三维动态增强血管成像(3D dynamic contrast enhancement magnetic resonance angiography,3DDCE MRA)技术参数对图像质量的影响。方法:106例行三维动态增强血管造影检查的病例,分为三组分别采用以下方法成像:①智能(smart)跟踪法;②test小剂量测试法;③经验法。同时将可变参数进行对比,采用SPSS 10.0统计软件,卡方检验和秩和检验对数据进行处理。结果:三组间图像质量差异具有显著性(P=0.038)。测试法成像质量优率最高。K空间中心充填和K空间顺序充填对图像质量的影响差异具有显著性(P=0.015),K空间中心充填图像质量好于K空间顺序充填。结论:3种3D DCE MRA成像方法中,test小剂量团注测试法是3D-DCE MRA成像最佳的延时时间计算方法,其成像质量最佳。高质量的3D DCE MRA图像依赖于患者的配合、合理的扫描序列及参数选择、最佳扫描延迟时间的把握、合理的造影剂剂量和注射速度。 Aim: To evaluate the effect of3D DCE MRA (3D dynamic contrast enhancement magnetic resonance angiography) technical parameter on image quality. Methods: One hundred and six cases of 3D-DCE-MRA were classified into 3 groups: smart tracing method, small dosage test method and experiential method and were compared, applying with SPSS 10. 0 statistical software, chi-square test and rank sum test. Results: The difference of image quality among these three group were obvious ( P = 0. 038 ) with greatest excellent imaging rate in the small dosage test group, and image quality with K-space center filling was better than that with K-space sequence filling. Conclusion:Of the three 3D DCE MRA, small dosage bolus injection test method is the best delay timing method with the imaging quality; excellent quality of 3D DCE MRA imaging depend upon patient's cooperation, rational scanning sequence and parameter selected, the decision of the best delay timing , appropriate contrast medium dosage and injection speed.
出处 《暨南大学学报(自然科学与医学版)》 CAS CSCD 北大核心 2007年第4期414-417,共4页 Journal of Jinan University(Natural Science & Medicine Edition)
关键词 磁共振成像 三维动态血管成像 扫描参数 扫描技术 MRI 3D-CE MRA scan parameter scan technique
  • 相关文献

参考文献4

二级参考文献16

  • 1[1]Lee VS, Martin DJ, Krinsky GA, et al. Gadiolinium-enhanced MR angiograhpy; artifacets and piffalls [J]. AJR, 2000, 175 ( 1 ):197-205.
  • 2[4]Poon E, Yucel EK, Pagan-Marin H, et al. Lliac artery stenosis measurements:comparison of two-flight and three-dimensional dynamic gadolinium enhanced MR angiography [J]. AJR, 1997, 169(4): 1139-1144.
  • 3[5]Foo TK, Saranathan M, Prince MR, et al. Automatic detection of bolus arrival time and initiation of data acquisition in fast, three-dimensional gadolinium-enhanced, MR angiography [J]. Radiology,1997,203(1) :275-280.
  • 4[7]Kopka L,.Vosshenrich R, Rodenwaldt J, et al. Differences in injection rate on contrast-enhanced breath-hold three-dimensional MR angiography[J]. AJR, 1998,170(4):345-348.
  • 5Giessing M, Kroencke TJ, Taupitz M, et al. Gadolinium-enhanced three-dimensional magnetic resonance angiography versus conventional digital subtraction angiography: which modality is superior in evaluating living kidney donors? Transplantation,2003,76(6):
  • 6Prince MR, Chenevert TL, Foo TK, et al. Contrast-enhanced abdominal MR angiography: optimization of imaging delay time by automating the detection of contrast materiall arrival in the aorta. Radiology, 1997,203(1):109
  • 7Wilman AH, Reiderer SJ, Huston J, et al. Arterial phase carotid and vertebral artery imaging in 3D contrast-enhanced MR angiography by combining fluoroscopic triggering with an elliptical centric acquisition order. Magn Reson Med,1998,40(1):24
  • 8Cosottini M, Pingitore A, Puglioli M, et al. Contrast-enhanced three-dimensional magnetic resonance angiolography of atherosclerotic internal carotid stenosis as the noninvasive imaging modality in revascularization decision making. Stroke, 2003,34(3):600
  • 9Goldman JP. New Techniques and applications for magnetic resonance angiography. The Mount Sinai Journal of Medicine, 2003,70(6):375
  • 10Haulon S, Lions C, Mcfadden EP, et al. Prospective evaluation of magnetic resonance imaging after endovascular treatment of infrarenal aortic aneurysms. Eur J Vasc Endovasc Surg,2001,22(1):62

共引文献24