期刊文献+

高效液相色谱法结合二阶校正方法用于复合维生素B三组分的同时定量测定 被引量:3

DETERMINATION OF VITAMIN B COMPLEX BY USING SECOND-ORDER CALIBRATION ALGORITHM COMBINING WITH HIGH PERFORMANCE LIQUID CHROMATOGRAPLY-DIODE ARRAY DETECTION
下载PDF
导出
摘要 应用HPLC-DAD结合2种具有数学分离功能部分代替物理分离的二阶校正方法,交替不对称三线性算法和双线性最小二乘算法,对复合维生素B类化合物进行了定量分析研究.在简单的色谱条件和谱峰严重重叠以及干扰存在下对感兴趣分析物进行了同时快速定量测定,取得了满意的预测结果. Vitamin B complex have been determined simultaneously by using two second-order calibration al- gorithms, Alternating asymmetric trilinear decomposition algorithm and Bilinear least-squares algorithm, coupled with high performance liquid chromatography-diode array detection. In the presence of interfering components and the simple performance condition, it showed the second-order calibration methods could quantify the analytes of interest from overlapped chromatographic profiles and give the accurate predicted results by utilizing "mathematical separation" instead of "physics separation".,
出处 《河南工业大学学报(自然科学版)》 CAS 北大核心 2007年第4期41-44,共4页 Journal of Henan University of Technology:Natural Science Edition
基金 河南工业大学博士基金资助项目(2006BS010)
关键词 复合维生素B 高效液相色谱 交替不对称三线性分解算法 双线性最小二乘算法 vitamin B complex high performance liquid chromatography alternating asymmetric trilinear decomposition algorithm bilinear least-squares algorithm.
  • 相关文献

参考文献10

  • 1陆帼蓉,王桂珍.RP-HPLC法测定复合维生素B片中维生素B_1、B_2、B_6和烟酰胺的含量[J].中国药科大学学报,1995,26(3):177-179. 被引量:30
  • 2刘要武,李叙琳.多种维生素的高效液相色谱分离及应用[J].分析试验室,1997,16(6):44-46. 被引量:14
  • 3李克,王华娟,潘朝晖,严晓星,夏培元.离子对反相高效液相色谱法同时测定复合维生素片中4种水溶性维生素[J].色谱,2003,21(1):66-68. 被引量:70
  • 4Ndaw S,Bergaentzlé M,Aoudé-Werner D,et al.Extraction procedures for the liquid chromatographic determination of thiamin,riboflavin and vitamin B6 in foodstuffs[J].Food Chemistry,2000,71(2):129-138.
  • 5Moreno P,Salvadó V.Determination of eight water-and fat-soluble vitamins in multi-vitamin pharmaceutical formulations by high-performance liquid chromatography[J].J Chromatogr A,2000,870(1 -2):207-215.
  • 6Booksh K S,Kowalski B R.Theory of analytical chemistry[J].Analytical Chemistry,1992,66:782-791.
  • 7Le-Qian Hu,Hai-Long Wu,Yu-Jie Ding,et al.Alternating asymmetric trilinear decomposition for three-way data arrays analysis and second-order calibration,chemometrics and intelligent laboratory systems[J].Chemom Intell Lab Syst,2006,82(1 -2):145-153.
  • 8Damiani P C,Nepote A J,Bearzotti M,et al.A test field for the second-order advantage in bilinear least-squares and parallel factor analyses:fluorescence determination of ciprofloxacin in human urine[J].Anal Chem,2004,76:2798-2806.
  • 9Bro R,Kiers H H L.A new efficient method for determining the number of components in PARAFAC modes[J].Journal of Chemom,2003,17:274-286.
  • 10Le-Qian Hu,Hai-Long Wu,Jian-Hui Jiang,et al.Use of pseudo-sample extraction and the projection technique to estimate the chemical rank of three-way data arrays[J].Analytical and Bioanalytical Chemistry,2006,384(7 -8):1493-1500.

二级参考文献21

共引文献103

同被引文献28

引证文献3

二级引证文献9

相关作者

内容加载中请稍等...