期刊文献+

开颅手术患者瑞芬太尼控制性降压的效果 被引量:8

原文传递
导出
摘要 瑞芬太尼可产生明显的降压作用,本研究拟观察开颅手术患者瑞芬太尼控制性降压的效果。
出处 《中华麻醉学杂志》 CAS CSCD 北大核心 2007年第7期665-666,共2页 Chinese Journal of Anesthesiology
基金 河北省科技攻关项目资助(042761490)
  • 相关文献

参考文献9

  • 1Schuttler J, Albrecht S, Breivik H, et al. A comparison of remifentanil and alfentanil in patients undergoing major abdominal surgery. Anaesthesia, 1997,52 : 307-317.
  • 2Hogne CW Jr, Bowdle TA, O'leary C, et al. A multicenter evaluation of total intravenous anesthesia with remifentanil and propofor for elective inpatient surgery. Anaesth Analg, 1996,83 : 279-285.
  • 3Haryadi DG, Orr JA, Kuck K, et al. partial CO2 rebreathing indirect Fick technique for non-invasive measurement of cardiac output. J Clin Monit Comput, 2000,16:361-374.
  • 4Botero M, Kirby D, Lobato EB, et al. Measurement of cardlca output before and after cardiopuimonary bypass : comparison among aortic transit- time ultrasound, thermodilution, and noninvasive partial CO2 rebreathing. J Cardiothorac Vasc Anesth, 2004,18 : 563-572.
  • 5Tsujimoto S, Arimura Y, Kuroda N, et al. Introduction and clinical evaluation of a new non-invasive cardica output monitor (NICO) based on Fick partial CO2 rebreathing method. Masul, 2001,50 : 799-804.
  • 6刘琼,黄纪坚.无创心输出量监测的进展与评价[J].中国呼吸与危重监护杂志,2003,2(6):379-381. 被引量:16
  • 7Pagel PS, Farber NE, Warltier DC. Cardiovascular pharmacology. In: Miller RD, ed. Anesthesia. 5th edn. Philadelphia:Churchill Livingstone publishers, 2000.104-105.
  • 8Noseir RK, Ficke DJ, Kundu A,et al. Sympathetic and vascular consequenences from remifentanil in humans. Anaesth Analg, 2003, 96: 1645-1650.
  • 9Shinohara K, Aono H, Unruh GK, et al. Suppressive effects of remifentanil on hemodynamics in baro-denervated rabbits. Can J Anaesth, 2000,47 : 361-366.

二级参考文献21

  • 1Koobi T,Kaukinen S,Ahola T,et al.Non-invasive measurement of cardiac output: whole-body impedance cardiography in simultaneous comparison with thermodilution and direct oxygen Fick methods.Intensive Care Med,1997;23:1132~1137
  • 2Weil MH.Electrical bioimpedance for noninvasive measurement of cardiac output.Crit Care Med,1997;25:1455
  • 3Sageman WS,Amundson DE.Thoracic electrical bioimpedance measurement of cardiac output in postaortocoronary bypass patients.Crit Care Med,1993;21:1139~1142
  • 4Keyl C,Rodig G,Lemberger P,et al.A comparision of the use of transesophageal dopper and thermodilution techniques for cardiac output detemination.Eur J Anaesthesiol,996;3:36~142
  • 5Valtier B,holley BP,elot JP.Noninvasive monitoring of cardiac output in critically ill patients using transesophageal Doppler.Am J Respir Crit Care Med,998;58:7~83
  • 6Pierpont G,eber RE,an FK,et al.Continuous cardiac output monitoring in patients using transtracheal Doppler ultrasound.J Cardiavascul Tech,1990;9:31
  • 7Singer M,Allen MJ,Webb AR.Effects of alterations in left ventricular filling,contractility,and systemic vascular resistance on the ascending aortic blood velocity waveform of normal subjects.Crit Care Med,1991;19:1138~1145
  • 8Patel M,Singer M.The optimal time for measuring the cardiorespiratory effects of positive end-expiratory pressure.Chest,1993;104:139~142
  • 9Freund PR.Transesophageal dopper scaning versus thermodilution during general anesthesia.Am J Surg,1987;153:490~503
  • 10Odenstedt H,Stenqvist O,Lundin S.Clinical evaluation of partial CO2 rebreathing technique for cardiac output monitoring in critically ill patients.Acta Anaesthesiol Scand,2002;46:152~159

共引文献15

同被引文献46

引证文献8

二级引证文献22

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部