摘要
目的比较采用克氏针内固定和微型钛板治疗掌、指骨骨折的临床效果。方法克氏针内固定治疗组42例45处骨折,术后随访1.5~12个月,平均8.4个月;微型钛板内固定治疗组28例36处骨折,术后随访2~12个月,平均9.2个月。以TAFS标准评价术后掌指关节及指间关节功能和术后感染及骨折愈合时间。结果克氏针固定组优良率为68.9%,微型钛板固定组优良率为80.6%,克氏针固定组与微型钛板组差异有显著意义(P<0.05)。克氏针组33处开放性骨折中5处发生感染;微型钛板组26处开放性骨折中3处发生感染。骨折愈合时间微型钛板组为7~12周,平均8.1周;克氏针组为6~12周,平均7.8周。结论从术后关节功能恢复的优良率、感染率以及骨折愈合时间相比,微型钛板组的疗效明显优于克氏针组,克氏针组骨折愈合时间较前者短。
Objective To compare the clinical results of metacarpal and phalanges fractures which were fixed with K-wires and Titanium mini-plate respectively.Methods 42 cases with 45 metacarpal or phalanges fractures were fixed by K-wires and were followed up for 8.4 months on average (range 1.5-12 months). 28 cases with 36 metacarpal or phalanges fractures were treated with Titanium mini-plates. FoUowing-up for this group was 9.2 months on average (range 2-12 months). Bone healing time and postoperative complications were recorded.Functions of metacarpal- phalanges inter-phalanges joints were evaluated using TAFS scales.Results According to TAFS scale, excellent and good rate of 68.9% was achieved in cases fixed with K-wires, while in cases treated with Titanium mini-plates the excellent and good rate were 80.6%. The differences between them were statistically significant(P 〈0.05). Among the 33 open fractures of the K- wire group, 5 had infections. There were 26 open fractures of the Titanium mini-plate group,3 of them had infection postoperatively. All the fractures healed. The average duration of the bone union was 8.1 weeks for the cases fixed with Titanium mini-plate and 7.8 weeks for those fixed with K-wires.Conclusion According to comparison of the joint function and postoperative infection between the two groups, fixation by Titanium mini-plates are more favorable in treating hand fractures than by using K- wires. But the duration of bone healing of the cases fixed with K-wire is short than the former.
出处
《实用手外科杂志》
2007年第3期144-146,共3页
Journal of Practical Hand Surgery
关键词
骨折
骨折内固定
掌骨
指骨
微型钛板
Fractures
Fracture internal fixation
Metacarpal, phalanges
Titanium mini-plate