固相萃取-差示脉冲伏安法测定牛黄解毒片的黄芩苷 被引量:2

Determination of Baicalin in Niuhuang Jiedu Pian by Electrochemical Method with Solid Phase Extract Technique
下载PDF
导出
摘要 目的研究黄芩苷在玻碳电极上的伏安行为,建立牛黄解毒片中黄芩苷的含量测定方法。方法Waters Plus—C18(1mL/50mg,30μm)固相萃取柱进行样品前处理,采用循环伏安法与差示脉冲伏安法研究黄芩苷在玻碳电极上的伏安行为。结果用20%甲醇1.0mL能完全洗脱黄芩苷;在pH3.0磷酸盐缓冲溶液中,黄芩苷的差示脉冲伏安峰电流与其浓度在1×10^-6~9×10^-5mol/L呈良好的线性关系,检测限为1×10^-7mol/L。结论本法简便、经济,灵敏度高,用于牛黄解毒片中黄芩苷的含量测定效果满意。 Objective To study the voltammetric behaviors of baicalin at the glassy carbon electrode and develop a method for the determination of baicalin in Niuhuang Jiedu Plan. Methods The pretreatment of sample was performed with a solid phase extract column, Waters Plus-C18(1 mL/50 mg, 30 μm). The electrochemical behavior of baicalin was investigated by using cyclic voltammetry and differential pulse voltammetry at the glassy carbon electrode. Results Using 25% methanol 1.0 mL as elution solution, the baicalin can be eluted completely from the solid phase extract column. In pH 3.0 phosphate buffer solution, the peak current of baicalin differential pulse voltammetry was dependent linearly on its concentration of baicalin over the range of 1×10^-6 - 9 ×10^-s mol/L with a detection limit of 1 ×10^-7 mol/L. Conclusion It is a convenient, economical and sensitive property for the determination of baicalin in Niuhuang jiedu plan with satisfactory results.
出处 《福建医科大学学报》 2007年第5期469-472,共4页 Journal of Fujian Medical University
基金 国家自然科学基金资助项目(20675015) 福建省教育厅资助省属高校项目(2005K049)
关键词 电化学 色谱法 固相萃取 牛黄解毒丸 黄芩苷 electrochemistry chromatography, solid phase extract niuhuang jiedu pill baicalin
  • 相关文献

参考文献8

二级参考文献22

  • 1[3]高昆玉编著. 色谱法在精细化工中的应用. 北京:中国石化出版社. 1996,395
  • 2[6]Humphries J M,Khachik F. Journal of Agricultural and Food Chemistry, 2003,51:1322
  • 3[7]Li Z, Wang L, Yang G Y et al. Journal of Chromatographic Science, 2003, 41(1):36
  • 4Susan S C Tai, Nancy Cargile, Charlie J Barnes. J Assoc Off Anal Chem, 1990,73(3) :368.
  • 5Kondo H, Binter M J. The assay of cyanocobalamin in pharmaceutical preparations by spectrophotometry[J]. J Aclin Invest, 1982, (70) :889.
  • 6Watanabe F, Takenaka S,Abe K, et al. Comparison of a microbiological assay and a fully automated chemiluminescent system for the determination of vitamin B12 in food[J]. J Agric Food chem, 1998,46:1433-1436.
  • 7L Ballesteros. Analytical use of the kinetics of complex formarion: Simultaneous determination of iron and cabalt by differential kinetic methods[J], Analyst, 2001,108(1285):443.
  • 8Surapote wongyain. Determination of vitamin B12 in multivitamin tablets by multimode high-performance liquid chromatography[J]. Journal of Chromatography A, 2000, (870):217-220.
  • 9Hiroshi Iwase. Ultramicrodetermination of cyanocobalamin in elemental diet by solid-phase extraction and high-performance liquid chromatography with visible detection [J].Journal of Chromatography, 1992, (590): 359-363.
  • 10Qiu-Ecao, Yunkun Zhao, Shu Qing Wu, et al. Study on the mechanism and applications of the fluorescence reactions among cobalt( Ⅱ ) ,H2O2 and two new derivatives of 8-sulfonamidoquinoline[J]. Talanta, 2000(51): 615-623.

共引文献82

同被引文献35

引证文献2

二级引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部