期刊文献+

热释电探测器特性参数动态响应测量 被引量:4

Dynamic Response Measurement of Pyroelectric Detector Parameters
下载PDF
导出
摘要 分析了热释电探测器对单脉冲辐射的响应,并组建了热释电探测器特性参数动态响应测试系统,利用相关检测原理检测热释电探测器的电压响应信号,提高了信噪比.设计了基于LabVIEW的测试软件,用此系统测试了热释电探测器对脉冲辐射的电压响应率Rv和归一化探测率D*,为热释电探测器参数测试提供了一种实用的全自动测试手段. The voltage response of pyroelectric detectors to pulse radiation was analyzed, Using lock-in amplifier based on correlation detection principle, response voltage was detected. A dynamic response measuring system of pyroelectric detector parameters was set up. Software was programmed based on LabVIEW. The proposed measuring system is used to measure the voltage responsibility and normal detect ratio of pyroelectric detector to pulse radiation. The result shows that it is a practical automatic system for measuring pyroelectric detector parameters.
出处 《西安工业大学学报》 CAS 2007年第3期205-208,共4页 Journal of Xi’an Technological University
基金 陕西省教育厅科研项目(06JK278)
关键词 热释电探测器 特性参数 电压响应率 归一化探测率 LABVIEW pyroelectric detector performance parameters voltage responsibility normal detect ratio LabVIEW
  • 相关文献

参考文献1

  • 1[4]Lang S B,Das-Gupta D K.Pyroelectricity:Fundamentals and Application[ J ].Ferroelectrics Review,2000(2):217.

同被引文献22

  • 1高教波,王军,骆延令,胡煜,王吉龙,高飞,郑雅卫.动态红外场景投射器研究新进展[J].红外与激光工程,2008,37(S2):351-354. 被引量:9
  • 2贺凤成,徐大雄,王本.热释电探测器及其两种新应用[J].北京邮电大学学报,1994,17(3):34-38. 被引量:3
  • 3闫军,庄乾章.热释电红外传感器的类别特性及应用[J].长春大学学报,2004,14(6):22-24. 被引量:11
  • 4刘茜,曾立波,雷俊锋,常静,郭宁宁.热释电红外检测器研究探讨[J].红外,2005,26(11):1-8. 被引量:6
  • 5FANG J S, HAO Q, BRADY D J, et al. Path-dependent human identification using a pyroelectric infrared sensor and Fresnel lens arrays[J]. Opt. Express, 2006(14):609- 624.
  • 6FANG J S, HAO Q, BRADY D J, et al. Real-time human identification using a pyroelectric infrared detector array and hidden Markov models[J].Opt. Express, 2006(14): 6643-6658.
  • 7FANG J S, HAO Q, BRADY D J, et al. A pyroelectric infrared biometric system for real-time walker recognition by use of a maximum likelihood principal components estimation (MLPCE) method[J]. Opt. Express, 2007(15):3271-3284.
  • 8GOPINATHAN U, BRADY D J, PITSIANIS N E Coded apertures for efficient pyroelectric motion tracking[J]. Opt. Express, 2003(11):2142-2152.
  • 9HAO Q, BRADY D J, GUENTHER B D, et al. Human tracking with wireless distributed pyroelectric sensors[J]. IEEE. Sensors Journal, 2006(6): 1683-1696.
  • 10SHANKAR M, BURCHETT J B, HAO Q, et al. Human-tracking systems using pyroelectric infrared detectors[J]. Optical Engineering, 2006(45): 106401-1-10.