期刊文献+

一种适用于电厂湿烟囱的长效防腐蚀涂料介绍 被引量:5

The Introduction of A Heavy-duty Durable Anti-corrosion Coating for Wet Stack Lining in Power Plant
下载PDF
导出
摘要 介绍一种适用于脱硫后的烟囱防腐蚀的长效特种涂料,该涂料具备高度耐腐蚀,高耐温度冲击性,高韧性,高耐磨性等诸多优点,并结合电厂烟囱脱硫后的实际情况,讨论了784涂料作为一种长效防腐蚀涂料的可行性,为新建脱硫烟囱采用的防腐蚀措施提供了一个新的选择,同时也为国内电厂旧烟囱的改造带来实际的参考。  In this paper, a heavy-duty durable anti-corrosion coating named 784 is introduced, which is of excellent anti-corrosion performance as well with outstanding thermal-impact, flexible and abrasion-resistance properties. Meanwhile the 784 coating was verified as a durable anti-corrosion alternative for wet stack in combination with the real application condition.
出处 《全面腐蚀控制》 2007年第5期26-30,13,共6页 Total Corrosion Control
关键词 湿烟囱 防腐蚀 涂料 784 脱硫 wet stack anti-corrosion coating 784 FGD