报告通过对高频高压发生器变压器的分析,利用全桥高频串联共振软开关频率调制逆变电路的方式,实现了180KV的高频高压油箱耐压测试系统的设计和制作。
In this paper,we analyze the transformer of X-ray high-voltage high-frequency generators and,have designed and implemented a high-voltage insulation testing system for its oil tank using full-bridge series resonant soft switching PFM DC-DC converter.
出处
《中国医疗器械杂志》
CAS
2007年第5期357-359,共3页
Chinese Journal of Medical Instrumentation
关键词
X线发生装置
变压器
绝缘测试系统
X-ray generator
transformer
insulation testing system